Serologické stanovení tularemie u myší použitím amperometrického imunosensoru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00022879" target="_blank" >RIV/00216224:14310/07:00022879 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00000493:G41__/07:#0000250
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Serological Diagnosis of Tularemia in Mice Using the Amperometric Immunosensor
Popis výsledku v původním jazyce
Tularemia caused by the bacterium Francisella tularensis belongs to danger infective diseases, therefore timely diagnosis is an important part of protective activities. A novel approach for serological diagnostics of tularemia using a four-channel amperometric immunosensor was proposed and evaluated on BALB/c mice as a model organism. The immunosensor was able to work with small volumes of serum samples (0.05 L per assay) and diagnosed tularemic infection very early after immunization. From the 5th day,it was possible to distinguish tularemic sera from control sera from mice immunized with Escherichia coli on the probability level of 0.99 (t-test). Some 40 measurements per one hour can be realized with the developed procedure. The obtained results were confirmed by the standard indirect ELISA. The proposed immunosensor-based approach seems promising for rapid detection of microbial pathogen infections.
Název v anglickém jazyce
Serological Diagnosis of Tularemia in Mice Using the Amperometric Immunosensor
Popis výsledku anglicky
Tularemia caused by the bacterium Francisella tularensis belongs to danger infective diseases, therefore timely diagnosis is an important part of protective activities. A novel approach for serological diagnostics of tularemia using a four-channel amperometric immunosensor was proposed and evaluated on BALB/c mice as a model organism. The immunosensor was able to work with small volumes of serum samples (0.05 L per assay) and diagnosed tularemic infection very early after immunization. From the 5th day,it was possible to distinguish tularemic sera from control sera from mice immunized with Escherichia coli on the probability level of 0.99 (t-test). Some 40 measurements per one hour can be realized with the developed procedure. The obtained results were confirmed by the standard indirect ELISA. The proposed immunosensor-based approach seems promising for rapid detection of microbial pathogen infections.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OSVTUO2006003" target="_blank" >OSVTUO2006003: BIODETEKCE - Studium nových metod detekce a identifikace bojových biologických prostředků</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
2507-2512
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—