Spojení mikrokolonových separací s MALDI MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00024581" target="_blank" >RIV/00216224:14310/07:00024581 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Coupling of microcolumn separations to MALDI MS
Popis výsledku v původním jazyce
Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are preferred ionization techniques in analysis of polymers. While ESI is usually chosen for on-line coupling of column separations to MS, MALDI is used for MS screening of large number of samples. Certain features of MALDI, however, make it more attractive in some applications: MALDI spectra, dominated by singly charged ions, are simpler and solid samples prepared on MALDI targets can be archived. This lecture will give an overview of approaches for coupling of microLC and CE with MALDI MS. The power of separation coupled a TOF/TOF instrument will be demonstrated on sensitive multidimensional analysis of complex biological samples. In conjunction with TOF mass spectrometer and high repetition rate lasers, extremely fast analyses can be achieved. The potential for high throughput MS analysis will be discussed on example of on-line and off-line analysis.
Název v anglickém jazyce
Coupling of microcolumn separations to MALDI MS
Popis výsledku anglicky
Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are preferred ionization techniques in analysis of polymers. While ESI is usually chosen for on-line coupling of column separations to MS, MALDI is used for MS screening of large number of samples. Certain features of MALDI, however, make it more attractive in some applications: MALDI spectra, dominated by singly charged ions, are simpler and solid samples prepared on MALDI targets can be archived. This lecture will give an overview of approaches for coupling of microLC and CE with MALDI MS. The power of separation coupled a TOF/TOF instrument will be demonstrated on sensitive multidimensional analysis of complex biological samples. In conjunction with TOF mass spectrometer and high repetition rate lasers, extremely fast analyses can be achieved. The potential for high throughput MS analysis will be discussed on example of on-line and off-line analysis.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Vienna
Název nakladatele resp. objednatele
University of Vienna
Verze
Mass Spec Forum
Identifikační číslo nosiče
—