Laser desorption ionization of red phosphorus clusters and their use for mass calibration in time-of-flight mass
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F09%3A00039767" target="_blank" >RIV/00216224:14310/09:00039767 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laser desorption ionization of red phosphorus clusters and their use for mass calibration in time-of-flight mass
Popis výsledku v původním jazyce
Phosphorus clusters P-n (n = 1-89) are easily formed from red phosphorus by laser desorption ionization (LDI) and they cover a range of up to approx. m/z 3000 in both positive and negative ion mode. The clusters are singly charged and the spectra are simple because phosphorus is monoisotopic. The mass spectra can be measured with an acceptable resolution and intensity. The use of positively charged P-n clusters for calibration in mass spectrometry was examined and it was demonstrated that in external calibration a standard deviation of +/-0.04 m/z units can be achieved even when using a common commercial matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instrument. When used as internal standards the P-n clusters react with some analytes - C-60 and C-70 fullerenes and cucurbituril[8], for example.
Název v anglickém jazyce
Laser desorption ionization of red phosphorus clusters and their use for mass calibration in time-of-flight mass
Popis výsledku anglicky
Phosphorus clusters P-n (n = 1-89) are easily formed from red phosphorus by laser desorption ionization (LDI) and they cover a range of up to approx. m/z 3000 in both positive and negative ion mode. The clusters are singly charged and the spectra are simple because phosphorus is monoisotopic. The mass spectra can be measured with an acceptable resolution and intensity. The use of positively charged P-n clusters for calibration in mass spectrometry was examined and it was demonstrated that in external calibration a standard deviation of +/-0.04 m/z units can be achieved even when using a common commercial matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instrument. When used as internal standards the P-n clusters react with some analytes - C-60 and C-70 fullerenes and cucurbituril[8], for example.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Rapid Communications in Mass Spectrometry
ISSN
0951-4198
e-ISSN
—
Svazek periodika
2009
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—