Development of halide sensor based on 4-(2-Pyridylazo)resorcinol (PAR)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F10%3A00046188" target="_blank" >RIV/00216224:14310/10:00046188 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of halide sensor based on 4-(2-Pyridylazo)resorcinol (PAR)
Popis výsledku v původním jazyce
Halide salts are used as raw materials in industrial processes and they are also present in natural mineral waters. Due to the wide impact of those anions on health and environment there is a need for fast, inexpensive and practical methods for halide anion determination. The azodyes are well known as widely utilized chromogenic reagents for determination of a number of metal ions. Unfortunately, their determination is in some cases hampered by the presence of interfering anions. This contribution discuss the results of the analysis of this phenomena for selected Tl(III)-PAR system which was employed for determination of iodide, bromide, and chloride after optimization of experimental conditions. Since the color change in aqueous solution caused by a ligand substitution reaction is sufficiently large, the studied system can be used as potential inexpensive halide chemosensor available for general practice. The attempt to analyze halide(s) in mixture was done by experimental data treatm
Název v anglickém jazyce
Development of halide sensor based on 4-(2-Pyridylazo)resorcinol (PAR)
Popis výsledku anglicky
Halide salts are used as raw materials in industrial processes and they are also present in natural mineral waters. Due to the wide impact of those anions on health and environment there is a need for fast, inexpensive and practical methods for halide anion determination. The azodyes are well known as widely utilized chromogenic reagents for determination of a number of metal ions. Unfortunately, their determination is in some cases hampered by the presence of interfering anions. This contribution discuss the results of the analysis of this phenomena for selected Tl(III)-PAR system which was employed for determination of iodide, bromide, and chloride after optimization of experimental conditions. Since the color change in aqueous solution caused by a ligand substitution reaction is sufficiently large, the studied system can be used as potential inexpensive halide chemosensor available for general practice. The attempt to analyze halide(s) in mixture was done by experimental data treatm
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů