A total beam compression of 5 and 10 corresponding to the asymmetry angles of 9 degrees and 12 degrees is achieved with V-5 and V-10 monochromators, respectively, in standard single crystal pure germanium (220) X-ray beam compressing (V-shaped) monochromators for CuK alpha(1) radiation. A higher 1D compression of X-ray beam is possible using larger angles of asymmetry, however it is achieved at the expense of the total intensity, which is decreased due to the refraction effect. To increase the monochromator intensity, several ways are considered both theoretically and experimentally. Linearly graded germanium rich GexSi(1-x) single crystal was used to prepare a V-21 single crystal monochromator with 15 degrees asymmetry angles (compression factor of 21). Its temperature gradient version is discussed for CuK alpha(1) radiation. X-ray diffraction measurements on the graded GeSi monochromator showed more than 3-times higher intensity at the output compared with that of a pure Ge monochrom
Název v anglickém jazyce
1D X-ray Beam Compressing Monochromators
Popis výsledku anglicky
A total beam compression of 5 and 10 corresponding to the asymmetry angles of 9 degrees and 12 degrees is achieved with V-5 and V-10 monochromators, respectively, in standard single crystal pure germanium (220) X-ray beam compressing (V-shaped) monochromators for CuK alpha(1) radiation. A higher 1D compression of X-ray beam is possible using larger angles of asymmetry, however it is achieved at the expense of the total intensity, which is decreased due to the refraction effect. To increase the monochromator intensity, several ways are considered both theoretically and experimentally. Linearly graded germanium rich GexSi(1-x) single crystal was used to prepare a V-21 single crystal monochromator with 15 degrees asymmetry angles (compression factor of 21). Its temperature gradient version is discussed for CuK alpha(1) radiation. X-ray diffraction measurements on the graded GeSi monochromator showed more than 3-times higher intensity at the output compared with that of a pure Ge monochrom
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
20th International Congress on X-Ray Optics and Microanalysis: AIP Conference Proceedings
ISBN
978-0-7354-0764-0
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
American Institute of Physics
Místo vydání
New York
Místo konání akce
Karlsruhe
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000278534600011