A New Aerosol Generation Technique for Elemental Mass Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F10%3A00046349" target="_blank" >RIV/00216224:14310/10:00046349 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A New Aerosol Generation Technique for Elemental Mass Spectrometry
Popis výsledku v původním jazyce
A new aerosol generation technique for elemental mass spectrometry. For introduction of samples to elemental analyzers, such as ICP MS, three techniques are routinely used: nebulization of liquid samples, laser ablation of solid samples and, for certainelements, volatile species generation. We have introduced substrate-assisted laser desorption (SALD) for off-line analysis of liquid samples recently; the method is advantageous for submicroliter sample analysis and for off-line coupling of ICP MS to microcolumn separations, such as capillary electrophoresis. Here we present a novel technique of aerosol generation for off-line elemental analysis of liquid samples. Unlike SALD, it does not require expensive pulse lasers. Samples for preliminary analyseswere prepared by pipetting submicroliter volumes of metal salt solutions on a suitable substrate.
Název v anglickém jazyce
A New Aerosol Generation Technique for Elemental Mass Spectrometry
Popis výsledku anglicky
A new aerosol generation technique for elemental mass spectrometry. For introduction of samples to elemental analyzers, such as ICP MS, three techniques are routinely used: nebulization of liquid samples, laser ablation of solid samples and, for certainelements, volatile species generation. We have introduced substrate-assisted laser desorption (SALD) for off-line analysis of liquid samples recently; the method is advantageous for submicroliter sample analysis and for off-line coupling of ICP MS to microcolumn separations, such as capillary electrophoresis. Here we present a novel technique of aerosol generation for off-line elemental analysis of liquid samples. Unlike SALD, it does not require expensive pulse lasers. Samples for preliminary analyseswere prepared by pipetting submicroliter volumes of metal salt solutions on a suitable substrate.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Salt Lake City, USA
Název nakladatele resp. objednatele
American Society for Mass Spectrometry
Verze
Proceedings of 58th ASMS Conference
Identifikační číslo nosiče
ASMS2010