Determination of Plant Thiols by Liquid Chromatography Coupled with Coulometric and Amperometric Detection in Lettuce Treated by Lead(II) Ions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F10%3A00046582" target="_blank" >RIV/00216224:14310/10:00046582 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/10:00160478 RIV/00216305:26210/10:PU89141
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Plant Thiols by Liquid Chromatography Coupled with Coulometric and Amperometric Detection in Lettuce Treated by Lead(II) Ions
Popis výsledku v původním jazyce
The main aim of this paper is to utilize high performance liquid chromatography with electrochemical detection for determination of thiols content in plants tissues of lettuce treated with lead(II) ions (0, 0.5 and 1 mM). We used two HPLC-ED instruments:HPLC coupled with one channel amperometric detector and HPLC coupled with twelve channel coulometric detector to detect simultaneously twelve thiols. The detection limits of thiols measured by CoulArray detector were about two magnitudes lower in comparison to those measured by Coulochem III detector and were from tens to hundreds pM. Under the optimal conditions, we utilized HPLC-CoulArray detector for analysis of tissues from lettuce plants. In addition, distribution and accumulation of lead ions with high spatial resolution was monitored using laser induced breakdown spectroscopy.
Název v anglickém jazyce
Determination of Plant Thiols by Liquid Chromatography Coupled with Coulometric and Amperometric Detection in Lettuce Treated by Lead(II) Ions
Popis výsledku anglicky
The main aim of this paper is to utilize high performance liquid chromatography with electrochemical detection for determination of thiols content in plants tissues of lettuce treated with lead(II) ions (0, 0.5 and 1 mM). We used two HPLC-ED instruments:HPLC coupled with one channel amperometric detector and HPLC coupled with twelve channel coulometric detector to detect simultaneously twelve thiols. The detection limits of thiols measured by CoulArray detector were about two magnitudes lower in comparison to those measured by Coulochem III detector and were from tens to hundreds pM. Under the optimal conditions, we utilized HPLC-CoulArray detector for analysis of tissues from lettuce plants. In addition, distribution and accumulation of lead ions with high spatial resolution was monitored using laser induced breakdown spectroscopy.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA522%2F07%2F0692" target="_blank" >GA522/07/0692: Studium tvorby thiolových sloučenin u rostlin - uplatnění při remediačních technologiích</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000278850200013
EID výsledku v databázi Scopus
—