Biosensors based on DNA or RNA aptamers, represent a very efficient platform for protein recognition1. We developed a novel label-free aptamer biosensing array for thrombin detection by measuring the electrochemical impedance upon aptamer-protein complexformation using gold CD-trodes (GCDT). GCDT are electrodes fabricated from recordable compact discs that contain a fine gold layer on their surface. Low-cost GCDTs present good versatility and acceptable reproducibility. The thrombin biosensor is constructed by self-assembling a thiol-modified aptamer onto a GCDT surface, followed by recognition of the protein via monitoring the interfacial electron transfer resistance in the presence of an [Fe(CN)6]3-/4- redox couple2,3. The aptasensor was also characterized by cyclic voltammetry and the individual binding steps were analysed by scanning electron microscopy.
Název v anglickém jazyce
APTAMER BASED CD-SENSORS FOR THROMBIN RECOGNITION BY MEANS OF ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY
Popis výsledku anglicky
Biosensors based on DNA or RNA aptamers, represent a very efficient platform for protein recognition1. We developed a novel label-free aptamer biosensing array for thrombin detection by measuring the electrochemical impedance upon aptamer-protein complexformation using gold CD-trodes (GCDT). GCDT are electrodes fabricated from recordable compact discs that contain a fine gold layer on their surface. Low-cost GCDTs present good versatility and acceptable reproducibility. The thrombin biosensor is constructed by self-assembling a thiol-modified aptamer onto a GCDT surface, followed by recognition of the protein via monitoring the interfacial electron transfer resistance in the presence of an [Fe(CN)6]3-/4- redox couple2,3. The aptasensor was also characterized by cyclic voltammetry and the individual binding steps were analysed by scanning electron microscopy.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů