Development of colorimetric chemodosimeter arrays for determination of anions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F11%3A00054682" target="_blank" >RIV/00216224:14310/11:00054682 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of colorimetric chemodosimeter arrays for determination of anions
Popis výsledku v původním jazyce
Halide (Cl-, Br-, I-) and hydrogencarbonate salt are important for maintaining homeostasis, environmental monitoring and are also present in foods and beverages such as in natural mineral waters. The azodyes such as 4-(2-pyridylazo)resorcinol (PAR) or 1-(2-pyridylazo)-2-naphtol (PAN) are widely utilized chromogenic reagents for determination of a number of metal ions. Unfortunately, the determination of metals is in some cases hampered by the presence of interfering anions, which impact the change in color of the dye-metal complex. However, we found that the change in color of some metal-azodye complexes may be utilized for determination of some anionic analytes. Since the color change in aqueous solution caused by a ligand substitution reaction is sufficiently large (cca. 50 nm), the studied systems were used to establish colorimetric chemodosimeter array devices for analysis of salt mixtures and mineral water samples.
Název v anglickém jazyce
Development of colorimetric chemodosimeter arrays for determination of anions
Popis výsledku anglicky
Halide (Cl-, Br-, I-) and hydrogencarbonate salt are important for maintaining homeostasis, environmental monitoring and are also present in foods and beverages such as in natural mineral waters. The azodyes such as 4-(2-pyridylazo)resorcinol (PAR) or 1-(2-pyridylazo)-2-naphtol (PAN) are widely utilized chromogenic reagents for determination of a number of metal ions. Unfortunately, the determination of metals is in some cases hampered by the presence of interfering anions, which impact the change in color of the dye-metal complex. However, we found that the change in color of some metal-azodye complexes may be utilized for determination of some anionic analytes. Since the color change in aqueous solution caused by a ligand substitution reaction is sufficiently large (cca. 50 nm), the studied systems were used to establish colorimetric chemodosimeter array devices for analysis of salt mixtures and mineral water samples.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů