Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F12%3A00057816" target="_blank" >RIV/00216224:14310/12:00057816 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ce-ce.org/cece2012/Proceedings%20CECE%202012%20Final+late%20abstracts_web.pdf" target="_blank" >http://www.ce-ce.org/cece2012/Proceedings%20CECE%202012%20Final+late%20abstracts_web.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis
Popis výsledku v původním jazyce
Amino acid profiling is sometimes considered to be a supplementary analysis for diagnostic purposes. Detection of amino acids by conventional spectrophotometric techniques is hindered by lack of chromophores in their structures, thus derivatization stepin a sample treatment protocol has to occur. However, amino acids in their native form can be detected by other detection techniques, e.g. mass spectrometry or capacitively coupled contactless conductivity detection (C4D). C4D is a non specific detectiontechnique suitable for detection of ionic species and was successfully used for determination of amino acids. Completely resolved peaks were obtained only when long capillaries and electro-osmotic flow (EOF) suppression were applied. However, effectiveseparation time of analytes of interest can be altered by EOF modification. Induction of the anodic EOF for amino acid profiling in the shorter capillaries is the subject of presented contribution.
Název v anglickém jazyce
Utilization of the anodic electro-osmotic flow for an amino acids profiling by capillary electrophoresis
Popis výsledku anglicky
Amino acid profiling is sometimes considered to be a supplementary analysis for diagnostic purposes. Detection of amino acids by conventional spectrophotometric techniques is hindered by lack of chromophores in their structures, thus derivatization stepin a sample treatment protocol has to occur. However, amino acids in their native form can be detected by other detection techniques, e.g. mass spectrometry or capacitively coupled contactless conductivity detection (C4D). C4D is a non specific detectiontechnique suitable for detection of ionic species and was successfully used for determination of amino acids. Completely resolved peaks were obtained only when long capillaries and electro-osmotic flow (EOF) suppression were applied. However, effectiveseparation time of analytes of interest can be altered by EOF modification. Induction of the anodic EOF for amino acid profiling in the shorter capillaries is the subject of presented contribution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
9th International Interdisciplinary Meeting on Bioanalysis
ISBN
9788090495913
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
235-239
Název nakladatele
Institute of Analytical Chemistry AS CR, v. v. i., Veveří 97, 602 00 Brno
Místo vydání
Brno, Czech Republic
Místo konání akce
Hotel Continental, Brno, Czech Republic
Datum konání akce
1. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—