X-Ray microtomography as a technique for mineralogical analysis of urinary calculi
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F12%3A00058646" target="_blank" >RIV/00216224:14310/12:00058646 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
X-Ray microtomography as a technique for mineralogical analysis of urinary calculi
Popis výsledku v původním jazyce
The aim of this study is to present synchrotron radiation X-ray microtomography (SR-uCT) as the technique for investigation of the mineralogical composition of urinary calculi fragments in the non destructive manner at very high resolution. SR uCT is proved to be an effective technique for determination of texture, 3D microstructure and composition of kidney stones. Since this technique is non-destructive, traditional analytical methods can also be performed. The comparison of the results obtained by SR-uCT analysis with those derived from current standard analytical approaches are in a good agreement. As the comparative method was used laser ablation inductively coupled plasma mass spectrometry.
Název v anglickém jazyce
X-Ray microtomography as a technique for mineralogical analysis of urinary calculi
Popis výsledku anglicky
The aim of this study is to present synchrotron radiation X-ray microtomography (SR-uCT) as the technique for investigation of the mineralogical composition of urinary calculi fragments in the non destructive manner at very high resolution. SR uCT is proved to be an effective technique for determination of texture, 3D microstructure and composition of kidney stones. Since this technique is non-destructive, traditional analytical methods can also be performed. The comparison of the results obtained by SR-uCT analysis with those derived from current standard analytical approaches are in a good agreement. As the comparative method was used laser ablation inductively coupled plasma mass spectrometry.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů