POCIS sampling in combination with ELISA: Screening of sulfonamide residues in surface and waste waters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F12%3A00059325" target="_blank" >RIV/00216224:14310/12:00059325 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60076658:12520/12:43883452 RIV/00027162:_____/12:#0000935
Výsledek na webu
<a href="http://dx.doi.org/10.1039/c1em10652j" target="_blank" >http://dx.doi.org/10.1039/c1em10652j</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c1em10652j" target="_blank" >10.1039/c1em10652j</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
POCIS sampling in combination with ELISA: Screening of sulfonamide residues in surface and waste waters
Popis výsledku v původním jazyce
The present paper shows the successful application of passive sampling using POCIS in combination with an immunochemical ELISA technique and HPLC/MS/MS analysis to study the distribution of sulfonamides in streams.Higher concentrations were determined inrivers at the city of Brno agglomeration. In agreement with other available studies, these findings indicate low efficiency of conventional waste water treatment plant to eliminate polar pharmaceuticals such as sulfonamides. Good performance and correlation with the LC/MS results, as well as ease of use, indicate good potential for the immunochemical ELISA technique to become the screening tool for sulfonamide determination in surface waters including passive samplers.
Název v anglickém jazyce
POCIS sampling in combination with ELISA: Screening of sulfonamide residues in surface and waste waters
Popis výsledku anglicky
The present paper shows the successful application of passive sampling using POCIS in combination with an immunochemical ELISA technique and HPLC/MS/MS analysis to study the distribution of sulfonamides in streams.Higher concentrations were determined inrivers at the city of Brno agglomeration. In agreement with other available studies, these findings indicate low efficiency of conventional waste water treatment plant to eliminate polar pharmaceuticals such as sulfonamides. Good performance and correlation with the LC/MS results, as well as ease of use, indicate good potential for the immunochemical ELISA technique to become the screening tool for sulfonamide determination in surface waters including passive samplers.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Environmental Monitoring
ISSN
1464-0325
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
250-257
Kód UT WoS článku
000298855800030
EID výsledku v databázi Scopus
—