Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F13%3A00066611" target="_blank" >RIV/00216224:14310/13:00066611 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26620/13:PU101649
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.sab.2012.12.009" target="_blank" >http://dx.doi.org/10.1016/j.sab.2012.12.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.sab.2012.12.009" target="_blank" >10.1016/j.sab.2012.12.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets
Popis výsledku v původním jazyce
Methods based on laser ablation, such as Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary calculi bulk and micro analysis. Investigation of spatial distribution of matrix and trace elements can help to explain their emergence and growth. However, quantification is still very problematic and these methods are often used only for qualitative elemental mapping. There are no commercially available standards, which would correspond to the urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. The aim of this study is to demonstrate the calibration capabilities and examine the limitations of laser ablation based techniques. Calibration pellets were prepared from powdered human urinary calculi with phosphate, oxalate and urate matrix.
Název v anglickém jazyce
Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets
Popis výsledku anglicky
Methods based on laser ablation, such as Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary calculi bulk and micro analysis. Investigation of spatial distribution of matrix and trace elements can help to explain their emergence and growth. However, quantification is still very problematic and these methods are often used only for qualitative elemental mapping. There are no commercially available standards, which would correspond to the urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. The aim of this study is to demonstrate the calibration capabilities and examine the limitations of laser ablation based techniques. Calibration pellets were prepared from powdered human urinary calculi with phosphate, oxalate and urate matrix.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Spectrochimica Acta B
ISSN
0584-8547
e-ISSN
—
Svazek periodika
81
Číslo periodika v rámci svazku
MAR 1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
43-49
Kód UT WoS článku
000315314500006
EID výsledku v databázi Scopus
—