Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00061405" target="_blank" >RIV/00216224:14740/12:00061405 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/12:PU101656
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
Popis výsledku v původním jazyce
Methods based on laser ablation, such as Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary stones bulk and micro analysis. The aim of this study is to demonstrate the calibration capabilities and limitations of these techniques. There are no commercially available standards, which would correspond to urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. Calibration pellets were prepared from human urinary stones with phosphate, oxalate and urate matrix. For this comparative study the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover some unconventional techniques such as simultaneous LIBS ? LA-ICP-OES and laser ablation (LA) ? LIBS were also utilized.
Název v anglickém jazyce
Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
Popis výsledku anglicky
Methods based on laser ablation, such as Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary stones bulk and micro analysis. The aim of this study is to demonstrate the calibration capabilities and limitations of these techniques. There are no commercially available standards, which would correspond to urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. Calibration pellets were prepared from human urinary stones with phosphate, oxalate and urate matrix. For this comparative study the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover some unconventional techniques such as simultaneous LIBS ? LA-ICP-OES and laser ablation (LA) ? LIBS were also utilized.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů