SENSITIVE DETERMINATION OF GLUTATHIONE IN VARIOUS BIOLOGICAL SAMPLES BY CAPILLARY ELECTROPHORESIS WITH GREEN LASER INDUCED FLUORESCENCE DETECTION
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F14%3A00083392" target="_blank" >RIV/00216224:14310/14:00083392 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SENSITIVE DETERMINATION OF GLUTATHIONE IN VARIOUS BIOLOGICAL SAMPLES BY CAPILLARY ELECTROPHORESIS WITH GREEN LASER INDUCED FLUORESCENCE DETECTION
Popis výsledku v původním jazyce
Laser induced fluorescence capillary electrophoresis (CE-LIF) with 515 nm green laser module was used for sensitive determination of glutathione (GSH) in various biological samples. For the first time, eosin-5-maleimide was used as a fluorescent tag in CE. Studies were performed to optimize the derivatization conditions (the ratio of reagent to analyte, the reaction time, temperature, etc.). CE-LIF also offers a unique opportunity to monitor the stability of the reagent and various reaction products. Wedemonstrate the applicability of the developed method on determination of GSH in real biological samples (exhaled breath condensate and saliva) with LODs as low as 180 pM.
Název v anglickém jazyce
SENSITIVE DETERMINATION OF GLUTATHIONE IN VARIOUS BIOLOGICAL SAMPLES BY CAPILLARY ELECTROPHORESIS WITH GREEN LASER INDUCED FLUORESCENCE DETECTION
Popis výsledku anglicky
Laser induced fluorescence capillary electrophoresis (CE-LIF) with 515 nm green laser module was used for sensitive determination of glutathione (GSH) in various biological samples. For the first time, eosin-5-maleimide was used as a fluorescent tag in CE. Studies were performed to optimize the derivatization conditions (the ratio of reagent to analyte, the reaction time, temperature, etc.). CE-LIF also offers a unique opportunity to monitor the stability of the reagent and various reaction products. Wedemonstrate the applicability of the developed method on determination of GSH in real biological samples (exhaled breath condensate and saliva) with LODs as low as 180 pM.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2014: 11TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS
ISBN
9788090495920
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
232-236
Název nakladatele
INST ANALYTICAL CHEMISTRY ASCR, V V I-IAC
Místo vydání
BRNO
Místo konání akce
Brno, CZECH REPUBLIC
Datum konání akce
20. 10. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000354547400077