VOLTAMMETRY OF GUANOSINE AND GUANOSINE MONOPHOSPHATE ON A PENCIL GRAPHITE ELECTRODE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F15%3A00083028" target="_blank" >RIV/00216224:14310/15:00083028 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/15:PU117275
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
VOLTAMMETRY OF GUANOSINE AND GUANOSINE MONOPHOSPHATE ON A PENCIL GRAPHITE ELECTRODE
Popis výsledku v původním jazyce
Guanosine (Guo) and guanosine monophosphate (GMP) are noted for their biological effects in human system. In this study, the voltammetry of Guo and GMP on pencil graphite electrode (PeGE) was studied. In the first voltammetric cycle, oxidation peaks at ca. 1.1 V vs. Ag/AgCl were observed for both compounds. In the second cycle at about 0.6 V for Guo and GMP an additional oxidation peak was found. The further electrochemical experiments indicated that the new peak corresponds to 8-oxoguanine moiety whichwas after the oxidation process of Guo or GMP adsorbed on PeGE surface. The intensity of 8-oxoguanine peak for Guo was higher than for the GMP, that is probably due to the effect of the phosphate group of GMP. The effect of pH on both the first and thesecond cycle is manifested by negative shift of oxidation signals with increasing of pH.
Název v anglickém jazyce
VOLTAMMETRY OF GUANOSINE AND GUANOSINE MONOPHOSPHATE ON A PENCIL GRAPHITE ELECTRODE
Popis výsledku anglicky
Guanosine (Guo) and guanosine monophosphate (GMP) are noted for their biological effects in human system. In this study, the voltammetry of Guo and GMP on pencil graphite electrode (PeGE) was studied. In the first voltammetric cycle, oxidation peaks at ca. 1.1 V vs. Ag/AgCl were observed for both compounds. In the second cycle at about 0.6 V for Guo and GMP an additional oxidation peak was found. The further electrochemical experiments indicated that the new peak corresponds to 8-oxoguanine moiety whichwas after the oxidation process of Guo or GMP adsorbed on PeGE surface. The intensity of 8-oxoguanine peak for Guo was higher than for the GMP, that is probably due to the effect of the phosphate group of GMP. The effect of pH on both the first and thesecond cycle is manifested by negative shift of oxidation signals with increasing of pH.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XV. Workshop of Physical Chemists and Electrochemists
ISBN
9788021078574
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
150-153
Název nakladatele
Masarykova univerzita
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
26. 5. 2015
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—