Quantifying the Effects of Temperature and Salinity on Partitioning of Hydrophobic Organic Chemicals to Silicone Rubber Passive Samplers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F15%3A00086674" target="_blank" >RIV/00216224:14310/15:00086674 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.acs.org/doi/abs/10.1021/acs.est.5b00286" target="_blank" >http://pubs.acs.org/doi/abs/10.1021/acs.est.5b00286</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.est.5b00286" target="_blank" >10.1021/acs.est.5b00286</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantifying the Effects of Temperature and Salinity on Partitioning of Hydrophobic Organic Chemicals to Silicone Rubber Passive Samplers
Popis výsledku v původním jazyce
Passive sampling is a widely applied technique to determine freely dissolved aqueous concentrations of hydrophobic organic chemicals (HOCs), such as polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Crucial to the measurementsare sampler-water partition coefficients, which are generally determined in the laboratory under standard conditions (in freshwater at 20 degrees C). Theoretically, however, the coefficients are dependent on environmental conditions, such as temperatureand salinity. Yet, there are insufficient experimental data in the scientific literature to prove this for different polymers. Several polymers are already being applied during field monitoring, however, and neglecting any effects may lead to impreciseresults. In the present study, we therefore quantified the effects of temperature and salinity on the sampler-water partition coefficients of PAHs and PCBs for silicone rubber, a material used in Dutch passive sampling monitoring campaign
Název v anglickém jazyce
Quantifying the Effects of Temperature and Salinity on Partitioning of Hydrophobic Organic Chemicals to Silicone Rubber Passive Samplers
Popis výsledku anglicky
Passive sampling is a widely applied technique to determine freely dissolved aqueous concentrations of hydrophobic organic chemicals (HOCs), such as polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Crucial to the measurementsare sampler-water partition coefficients, which are generally determined in the laboratory under standard conditions (in freshwater at 20 degrees C). Theoretically, however, the coefficients are dependent on environmental conditions, such as temperatureand salinity. Yet, there are insufficient experimental data in the scientific literature to prove this for different polymers. Several polymers are already being applied during field monitoring, however, and neglecting any effects may lead to impreciseresults. In the present study, we therefore quantified the effects of temperature and salinity on the sampler-water partition coefficients of PAHs and PCBs for silicone rubber, a material used in Dutch passive sampling monitoring campaign
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Environmental Science and Technology
ISSN
0013-936X
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
6791-6799
Kód UT WoS článku
000355779100051