Dual carbonate sensor based on Eu(III) complex of DO3A ligand
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F16%3A00087994" target="_blank" >RIV/00216224:14310/16:00087994 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26620/16:PU126010
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-016-1722-x" target="_blank" >http://dx.doi.org/10.1007/s00706-016-1722-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-016-1722-x" target="_blank" >10.1007/s00706-016-1722-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dual carbonate sensor based on Eu(III) complex of DO3A ligand
Popis výsledku v původním jazyce
Eu(III) ternary complexes with 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) and picolinate-like "antenna" ligands ([Eu(DO3A)(L)](-)) react with carbonate anion to form more stable [Eu(DO3A)(CO3)](2-) complexes which are non-fluorescent. Furthermore, [Eu(DO3A)(L)](-) and [Eu(DO3A)(CO3)](2-) differ in their electrochemical behavior. [Eu(DO3A)(L)](-) are therefore suggested as sensitive luminescence-based and also electrochemical sensors of carbonate anion. Both luminescence and voltammetric sensing strategies show similar analytical figures of merit (limit of detection 0.2 mM, dynamic range 0.2-1.6 mM). The voltammetric procedure was successfully tested in field conditions for the quantitative analysis of bicarbonate/carbonate in environmental water samples, utilizing portable potentiostat and screen-printed electrode.
Název v anglickém jazyce
Dual carbonate sensor based on Eu(III) complex of DO3A ligand
Popis výsledku anglicky
Eu(III) ternary complexes with 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) and picolinate-like "antenna" ligands ([Eu(DO3A)(L)](-)) react with carbonate anion to form more stable [Eu(DO3A)(CO3)](2-) complexes which are non-fluorescent. Furthermore, [Eu(DO3A)(L)](-) and [Eu(DO3A)(CO3)](2-) differ in their electrochemical behavior. [Eu(DO3A)(L)](-) are therefore suggested as sensitive luminescence-based and also electrochemical sensors of carbonate anion. Both luminescence and voltammetric sensing strategies show similar analytical figures of merit (limit of detection 0.2 mM, dynamic range 0.2-1.6 mM). The voltammetric procedure was successfully tested in field conditions for the quantitative analysis of bicarbonate/carbonate in environmental water samples, utilizing portable potentiostat and screen-printed electrode.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
—
Svazek periodika
147
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
10
Strana od-do
925-934
Kód UT WoS článku
000374172200011
EID výsledku v databázi Scopus
—