Pulse Biamperometry for Electrochemical Detection in Flow Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F17%3A00113623" target="_blank" >RIV/00216224:14310/17:00113623 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.bestservis.eu/upload/file/Sbornik_metody17.pdf" target="_blank" >https://www.bestservis.eu/upload/file/Sbornik_metody17.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Pulse Biamperometry for Electrochemical Detection in Flow Systems
Popis výsledku v původním jazyce
A novel, pulse biamperometric technique was developed for enhancing the intensity of currents measured during electrochemical detection in flow systems. Two polarizable elctrodes in form of microfibers made of carbon platinum or their combination were utilized for biamperometric detection of dopamine in capillary detectors. Using a sequence of positive and negative potentials, measured signals were two orders of magnitude higher than those obtained for direct biamperometry. Such amplification resulted in forty times increase in sensitivity for dopamine detection. In a pulse mode, the passivation of electrodes was significantly reduced and the repeatability of individiual injections was markedly imporved.
Název v anglickém jazyce
Pulse Biamperometry for Electrochemical Detection in Flow Systems
Popis výsledku anglicky
A novel, pulse biamperometric technique was developed for enhancing the intensity of currents measured during electrochemical detection in flow systems. Two polarizable elctrodes in form of microfibers made of carbon platinum or their combination were utilized for biamperometric detection of dopamine in capillary detectors. Using a sequence of positive and negative potentials, measured signals were two orders of magnitude higher than those obtained for direct biamperometry. Such amplification resulted in forty times increase in sensitivity for dopamine detection. In a pulse mode, the passivation of electrodes was significantly reduced and the repeatability of individiual injections was markedly imporved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVII MODERNI ELEKTROCHEMICKE METODY
ISBN
9788090522152
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
104-107
Název nakladatele
LENKA SRSENOVA-BEST SERVIS
Místo vydání
USTI NAD LABEM
Místo konání akce
Jetrichovice, CZECH REPUBLIC
Datum konání akce
15. 5. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000432424300023