A compact bipolar electrochemistry device utilizing a liquid free catholyte and eye visual indication of the reporting event for the determination of antioxidant capacity in real-world samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F20%3A00115883" target="_blank" >RIV/00216224:14310/20:00115883 - isvavai.cz</a>
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S0039914020306044?token=4CBB19CF095E2AB89E2FA8C6CC86C8A1A6E769C67FB201E829B32F8927EE225BC2CBB3E727AAA7887551CD488B8305EA" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S0039914020306044?token=4CBB19CF095E2AB89E2FA8C6CC86C8A1A6E769C67FB201E829B32F8927EE225BC2CBB3E727AAA7887551CD488B8305EA</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2020.121313" target="_blank" >10.1016/j.talanta.2020.121313</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A compact bipolar electrochemistry device utilizing a liquid free catholyte and eye visual indication of the reporting event for the determination of antioxidant capacity in real-world samples
Popis výsledku v původním jazyce
Here we report for the first time the development of a compact, closed bipolar electrochemistry (BPE) device for the determination of antioxidant capacity in real-world samples by recording the onset driving voltage at which an eye-visible reporting event at the cathode pole of bipolar electrode (BE) occurs. The BPE cell consists of two distinct anode and cathode compartments that are electrically connected through a platinum wire BE. The anode pole of the BE is covered by a cellulose acetate thin film to prevent the fouling of the surface, while the cathode pole is embedded into an agarose hydrogel containing phenolphthalein, i.e., an acid-base indicator. The method relies on the oxidation of the reducing compounds in the sample by a fixed amount of H2O2 and the electro oxidation of the remaining H2O2 in the anode pole of the BE. This reaction triggers the reduction of water at the cathodic pole accompanied by the production of hydroxyl ions at different, H2O2 concentration-dependent onset driving voltages. The resulting increase of pH at the cathode pole results in the formation of a pink spot (reporting event), which is visible by the unaided eye. The applicability of the BPE device for the determination of antioxidant capacity in fruit juices and sodas is demonstrated. The analytical results, expressed as Trolox (TEAC) or Vitamin C (CVEAC) equivalent antioxidant capacity, correlate well with those obtained by the CUPRAC method.
Název v anglickém jazyce
A compact bipolar electrochemistry device utilizing a liquid free catholyte and eye visual indication of the reporting event for the determination of antioxidant capacity in real-world samples
Popis výsledku anglicky
Here we report for the first time the development of a compact, closed bipolar electrochemistry (BPE) device for the determination of antioxidant capacity in real-world samples by recording the onset driving voltage at which an eye-visible reporting event at the cathode pole of bipolar electrode (BE) occurs. The BPE cell consists of two distinct anode and cathode compartments that are electrically connected through a platinum wire BE. The anode pole of the BE is covered by a cellulose acetate thin film to prevent the fouling of the surface, while the cathode pole is embedded into an agarose hydrogel containing phenolphthalein, i.e., an acid-base indicator. The method relies on the oxidation of the reducing compounds in the sample by a fixed amount of H2O2 and the electro oxidation of the remaining H2O2 in the anode pole of the BE. This reaction triggers the reduction of water at the cathodic pole accompanied by the production of hydroxyl ions at different, H2O2 concentration-dependent onset driving voltages. The resulting increase of pH at the cathode pole results in the formation of a pink spot (reporting event), which is visible by the unaided eye. The applicability of the BPE device for the determination of antioxidant capacity in fruit juices and sodas is demonstrated. The analytical results, expressed as Trolox (TEAC) or Vitamin C (CVEAC) equivalent antioxidant capacity, correlate well with those obtained by the CUPRAC method.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
219
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
„121313“
Kód UT WoS článku
000568702400005
EID výsledku v databázi Scopus
2-s2.0-85086995056