Time integrative sampling properties of Speedisk and silicone rubber passive samplers determined by chemical analysis and in vitro bioassay testing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F20%3A00117358" target="_blank" >RIV/00216224:14310/20:00117358 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0045653520316921?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0045653520316921?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2020.127498" target="_blank" >10.1016/j.chemosphere.2020.127498</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time integrative sampling properties of Speedisk and silicone rubber passive samplers determined by chemical analysis and in vitro bioassay testing
Popis výsledku v původním jazyce
Compared to grab samples, passive samplers have the advantage that they sample over a longer time period and can detect lower compound concentrations in water quality monitoring campaigns. To allow the determination of time-weighted average concentrations, however, sampler uptake should remain linear in time over the entire sampling period. Therefore, the time integrative or linear uptake properties of adsorption-based Speedisks and partitioning-based silicone rubber samplers were assessed with respect to chemically analyzed single compounds and measured bioactivity in in vitro bioassays. Both sampler types were deployed in consecutive and overlapping time series in a WTTP effluent and in the river Meuse up to 105 days. Extracts were chemically analyzed for PCBs, PAHs and pesticides and tested in the Aliivibrio fischeri and DR-LUC bioassays. Speedisks showed time integrative sampling for the detected pesticides as well as for bioassay responses at both sampling locations for the entire sampling period. The silicone rubber samplers showed poor linear uptake in time for the unknown compounds causing bioassay responses. The bioassay results indicate that conversion of a bioassay response to a passive sampler extract into a time-weighted average bioactivity per liter water seems justified for Speedisks, confirming that concentrations in the samplers correspond to a single volume of sampled water for all compounds. The bioassay results also indicate that a similar conversion for silicone rubber extracts should be interpreted with caution. In principle, it is actually impossible, because the concentration of each compound contributing to the bioassay response corresponds to a different sampled water volume.
Název v anglickém jazyce
Time integrative sampling properties of Speedisk and silicone rubber passive samplers determined by chemical analysis and in vitro bioassay testing
Popis výsledku anglicky
Compared to grab samples, passive samplers have the advantage that they sample over a longer time period and can detect lower compound concentrations in water quality monitoring campaigns. To allow the determination of time-weighted average concentrations, however, sampler uptake should remain linear in time over the entire sampling period. Therefore, the time integrative or linear uptake properties of adsorption-based Speedisks and partitioning-based silicone rubber samplers were assessed with respect to chemically analyzed single compounds and measured bioactivity in in vitro bioassays. Both sampler types were deployed in consecutive and overlapping time series in a WTTP effluent and in the river Meuse up to 105 days. Extracts were chemically analyzed for PCBs, PAHs and pesticides and tested in the Aliivibrio fischeri and DR-LUC bioassays. Speedisks showed time integrative sampling for the detected pesticides as well as for bioassay responses at both sampling locations for the entire sampling period. The silicone rubber samplers showed poor linear uptake in time for the unknown compounds causing bioassay responses. The bioassay results indicate that conversion of a bioassay response to a passive sampler extract into a time-weighted average bioactivity per liter water seems justified for Speedisks, confirming that concentrations in the samplers correspond to a single volume of sampled water for all compounds. The bioassay results also indicate that a similar conversion for silicone rubber extracts should be interpreted with caution. In principle, it is actually impossible, because the concentration of each compound contributing to the bioassay response corresponds to a different sampled water volume.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemosphere
ISSN
0045-6535
e-ISSN
—
Svazek periodika
259
Číslo periodika v rámci svazku
November 2020
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
1-11
Kód UT WoS článku
000566573600101
EID výsledku v databázi Scopus
2-s2.0-85087685249