Towards harmonised criteria in quality assurance and quality control of suspect and non-target LC-HRMS analytical workflows for screening of emerging contaminants in human biomonitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F21%3A00122041" target="_blank" >RIV/00216224:14310/21:00122041 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0165993621000236?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0165993621000236?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.trac.2021.116201" target="_blank" >10.1016/j.trac.2021.116201</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Towards harmonised criteria in quality assurance and quality control of suspect and non-target LC-HRMS analytical workflows for screening of emerging contaminants in human biomonitoring
Popis výsledku v původním jazyce
Although the exposure assessment of chemicals of emerging concern (CECs) has taken a decisive step forward through advances in (bio)informatics, statistics, and the development of highly sophisticated analytical instruments, the lack of standardisation and harmonisation of analytical workflows and method performance assessment for suspect and non-target screening hampers the interpretation of results, their comparability and thus, its transmission to policymakers. To date, unlike in other research fields such as forensics or food analysis, there is a lack of guidelines for non-target analysis in human risk assessment and quality assurance and quality control (QA/QC) protocols. Moreover, the majority of efforts have been focused on the development and implementation of QA/QC actions for data acquisition, data analysis and mining, largely neglecting the sample preparation necessary for determination of CECs by suspect and non-target screening methods. In this article, we propose a set of QA/QC measures that covers sampling, sample preparation and data acquisition, as an aspect of work conducted within the European Biomonitoring for Europe initiative (HBM4EU). These measures include the use of standardised terminology and the implementation of dedicated QA/QC actions in each stage of the analytical process. Moreover, a framework for the analytical performance assessment has been developed for the first time for the identification of CECs in human samples by suspect and non-target approaches. Adoption of the actions proposed here for the identifi-cation of CECs in human matrices can significantly improve the comparability of reported results and contribute to the (challenging) Exposome research field.
Název v anglickém jazyce
Towards harmonised criteria in quality assurance and quality control of suspect and non-target LC-HRMS analytical workflows for screening of emerging contaminants in human biomonitoring
Popis výsledku anglicky
Although the exposure assessment of chemicals of emerging concern (CECs) has taken a decisive step forward through advances in (bio)informatics, statistics, and the development of highly sophisticated analytical instruments, the lack of standardisation and harmonisation of analytical workflows and method performance assessment for suspect and non-target screening hampers the interpretation of results, their comparability and thus, its transmission to policymakers. To date, unlike in other research fields such as forensics or food analysis, there is a lack of guidelines for non-target analysis in human risk assessment and quality assurance and quality control (QA/QC) protocols. Moreover, the majority of efforts have been focused on the development and implementation of QA/QC actions for data acquisition, data analysis and mining, largely neglecting the sample preparation necessary for determination of CECs by suspect and non-target screening methods. In this article, we propose a set of QA/QC measures that covers sampling, sample preparation and data acquisition, as an aspect of work conducted within the European Biomonitoring for Europe initiative (HBM4EU). These measures include the use of standardised terminology and the implementation of dedicated QA/QC actions in each stage of the analytical process. Moreover, a framework for the analytical performance assessment has been developed for the first time for the identification of CECs in human samples by suspect and non-target approaches. Adoption of the actions proposed here for the identifi-cation of CECs in human matrices can significantly improve the comparability of reported results and contribute to the (challenging) Exposome research field.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_027%2F0008360" target="_blank" >EF16_027/0008360: Postdoc@MUNI</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
TrAC Trends in Analytical Chemistry
ISSN
0165-9936
e-ISSN
—
Svazek periodika
136
Číslo periodika v rámci svazku
March 2021
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
000637644000003
EID výsledku v databázi Scopus
2-s2.0-85100644895