Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00126753" target="_blank" >RIV/00216224:14310/22:00126753 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.acs.org/doi/10.1021/acs.analchem.2c00061" target="_blank" >https://pubs.acs.org/doi/10.1021/acs.analchem.2c00061</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.analchem.2c00061" target="_blank" >10.1021/acs.analchem.2c00061</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study
Popis výsledku v původním jazyce
A set of quality assurance/quality control (QA/QC) criteria for nontargeted measurement of pesticide exposure markers in a large-scale study of human urine has been proposed and applied across five laboratories within the HBM4EU project. Quality control material, including reference standards and fortified pooled urine samples (QC urine) were prepared in a centralized way and distributed across participants to monitor analytical performance and consistency of the liquid chromatography coupled to high-resolution mass spectrometry data generated with a harmonized workflow. Signal intensities, mass accuracy, and retention times of selected QA/QC markers covering a broad range of physicochemical properties were monitored across QC solvent standards, QC urine samples, study urine samples, and procedural blanks, setting acceptance thresholds for repeatability and accuracy. Overall, results showed high repeatability of the collected data. The RSDs of the signal intensities were typically below 20-30% in QC and study samples, with good stability of the chromatographic separation (retention time drift within 2-4 s intrabatch and 5 s interbatch) and excellent mass accuracy (average error < 2 ppm). The use of the proposed criteria allowed for the identification of handling errors, instrumental issues, and potential batch effects. This is the first elaboration of harmonized QA/QC criteria applied across multiple laboratories to assess the quality of data generated by nontargeted analysis of human samples.
Název v anglickém jazyce
Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study
Popis výsledku anglicky
A set of quality assurance/quality control (QA/QC) criteria for nontargeted measurement of pesticide exposure markers in a large-scale study of human urine has been proposed and applied across five laboratories within the HBM4EU project. Quality control material, including reference standards and fortified pooled urine samples (QC urine) were prepared in a centralized way and distributed across participants to monitor analytical performance and consistency of the liquid chromatography coupled to high-resolution mass spectrometry data generated with a harmonized workflow. Signal intensities, mass accuracy, and retention times of selected QA/QC markers covering a broad range of physicochemical properties were monitored across QC solvent standards, QC urine samples, study urine samples, and procedural blanks, setting acceptance thresholds for repeatability and accuracy. Overall, results showed high repeatability of the collected data. The RSDs of the signal intensities were typically below 20-30% in QC and study samples, with good stability of the chromatographic separation (retention time drift within 2-4 s intrabatch and 5 s interbatch) and excellent mass accuracy (average error < 2 ppm). The use of the proposed criteria allowed for the identification of handling errors, instrumental issues, and potential batch effects. This is the first elaboration of harmonized QA/QC criteria applied across multiple laboratories to assess the quality of data generated by nontargeted analysis of human samples.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical chemistry
ISSN
0003-2700
e-ISSN
1520-6882
Svazek periodika
94
Číslo periodika v rámci svazku
22
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
7833-7843
Kód UT WoS článku
000818957300001
EID výsledku v databázi Scopus
2-s2.0-85131839239