Detection of Single Ag Nanoparticles Using Laser Desorption/Ionization Mass Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F23%3A00131251" target="_blank" >RIV/00216224:14310/23:00131251 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.acs.org/doi/10.1021/jasms.3c00137" target="_blank" >https://pubs.acs.org/doi/10.1021/jasms.3c00137</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/jasms.3c00137" target="_blank" >10.1021/jasms.3c00137</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Single Ag Nanoparticles Using Laser Desorption/Ionization Mass Spectrometry
Popis výsledku v původním jazyce
The detection of a single entity (molecule, cell, particle, etc.) was always a challenging subject. Here we demonstrate the detection of single Ag nanoparticles (NPs) using subatmospheric pressure laser desorption/ionization mass spectrometry (LDI MS). The sample preparation, measurement conditions, generated ions, and limiting experimental factors are discussed here. We detected from 84 to 95% of the deposited 80 nm Ag NPs. The presented LDI MS platform is an alternative to laser ablation inductively coupled plasma mass spectrometry for imaging distribution of individual NPs across the sample surface and has a great potential for multiplexed mapping of low-abundance biomarkers in tissues.
Název v anglickém jazyce
Detection of Single Ag Nanoparticles Using Laser Desorption/Ionization Mass Spectrometry
Popis výsledku anglicky
The detection of a single entity (molecule, cell, particle, etc.) was always a challenging subject. Here we demonstrate the detection of single Ag nanoparticles (NPs) using subatmospheric pressure laser desorption/ionization mass spectrometry (LDI MS). The sample preparation, measurement conditions, generated ions, and limiting experimental factors are discussed here. We detected from 84 to 95% of the deposited 80 nm Ag NPs. The presented LDI MS platform is an alternative to laser ablation inductively coupled plasma mass spectrometry for imaging distribution of individual NPs across the sample surface and has a great potential for multiplexed mapping of low-abundance biomarkers in tissues.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the American Society for Mass Spectrometry
ISSN
1044-0305
e-ISSN
1879-1123
Svazek periodika
34
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1459-1466
Kód UT WoS článku
001006215900001
EID výsledku v databázi Scopus
2-s2.0-85163453596