Pathogen sensing device based on 2D MoS2/graphene heterostructure.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F23%3A00131702" target="_blank" >RIV/00216224:14310/23:00131702 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.snb.2023.134105" target="_blank" >https://doi.org/10.1016/j.snb.2023.134105</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2023.134105" target="_blank" >10.1016/j.snb.2023.134105</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pathogen sensing device based on 2D MoS2/graphene heterostructure.
Popis výsledku v původním jazyce
In this work we propose a new methodology for selective and sensitive pathogen detection based on a 2D layered heterostructured biosensing platform. As a proof of concept, we have chosen SARS-CoV-2 virus because the availability of new methods to detect this virus is still a great deal of interest. The prepared platform is based on the covalent immobilization of molybdenum disulphide functionalized with a diazonium salt (f-MoS2) onto graphene screen-printed electrodes (GPH SPE) by electrografting of the diazonium salt. This chemistry-based method generates an improved heterostructured biosensing platform for aptamer immobilization and aptasensor development. Electrochemical impedance spectroscopy (EIS) is used to obtain the signal response of the device, proving the ability of the sensor platform to detect the virus. SARS-CoV-2 spike RBD recombinant protein (SARS-CoV-2 S1 protein) has been detected and quantified with a low detection limit of 2.10 fg/mL. The selectivity of the developed biosensor has been confirmed after detecting the S1 protein even in presence of other interfering proteins. Moreover, the ability of the device to detect SARS-CoV-2 S1 protein has been also tested in nasopharyngeal swab samples.
Název v anglickém jazyce
Pathogen sensing device based on 2D MoS2/graphene heterostructure.
Popis výsledku anglicky
In this work we propose a new methodology for selective and sensitive pathogen detection based on a 2D layered heterostructured biosensing platform. As a proof of concept, we have chosen SARS-CoV-2 virus because the availability of new methods to detect this virus is still a great deal of interest. The prepared platform is based on the covalent immobilization of molybdenum disulphide functionalized with a diazonium salt (f-MoS2) onto graphene screen-printed electrodes (GPH SPE) by electrografting of the diazonium salt. This chemistry-based method generates an improved heterostructured biosensing platform for aptamer immobilization and aptasensor development. Electrochemical impedance spectroscopy (EIS) is used to obtain the signal response of the device, proving the ability of the sensor platform to detect the virus. SARS-CoV-2 spike RBD recombinant protein (SARS-CoV-2 S1 protein) has been detected and quantified with a low detection limit of 2.10 fg/mL. The selectivity of the developed biosensor has been confirmed after detecting the S1 protein even in presence of other interfering proteins. Moreover, the ability of the device to detect SARS-CoV-2 S1 protein has been also tested in nasopharyngeal swab samples.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10400 - Chemical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B: Chemical
ISSN
0925-4005
e-ISSN
0925-4005
Svazek periodika
392
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
001058370400001
EID výsledku v databázi Scopus
2-s2.0-85162142016