Single particle inductively coupled plasma mass spectrometry imaging of immunochemically labeled spheroid sections
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F23%3A00134084" target="_blank" >RIV/00216224:14310/23:00134084 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single particle inductively coupled plasma mass spectrometry imaging of immunochemically labeled spheroid sections
Popis výsledku v původním jazyce
Spheroids are one of the 3D biological models in which the arrangement of proliferating and necrotic cells resembles the tumor microenvironment. One of the markers of proliferation is Ki-67 protein, which is expressed by cells in the active phase of the cell cycle. Immunohistochemical labeling with a primary antibody and a fluorophore-labeled secondary antibody followed by fluorescence microscopy analysis is commonly employed for two- and three-dimensional imaging of the target protein in spheroid sections. We have successfully switched from fluorophore labeling of Ki-67 to nanoparticle labeling combined with LA ICP MS.* Recently, gold nanoparticles were used as very sensitive immunochemical tags in conventional UV laser ablation ICP MSI.1,2 In our approach, intact 20 nm gold nanoparticles tags were desorbed from the spheroid section with 2 940 nm laser ablation system.
Název v anglickém jazyce
Single particle inductively coupled plasma mass spectrometry imaging of immunochemically labeled spheroid sections
Popis výsledku anglicky
Spheroids are one of the 3D biological models in which the arrangement of proliferating and necrotic cells resembles the tumor microenvironment. One of the markers of proliferation is Ki-67 protein, which is expressed by cells in the active phase of the cell cycle. Immunohistochemical labeling with a primary antibody and a fluorophore-labeled secondary antibody followed by fluorescence microscopy analysis is commonly employed for two- and three-dimensional imaging of the target protein in spheroid sections. We have successfully switched from fluorophore labeling of Ki-67 to nanoparticle labeling combined with LA ICP MS.* Recently, gold nanoparticles were used as very sensitive immunochemical tags in conventional UV laser ablation ICP MSI.1,2 In our approach, intact 20 nm gold nanoparticles tags were desorbed from the spheroid section with 2 940 nm laser ablation system.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-12262S" target="_blank" >GA21-12262S: Nanočásticové sondy pro zobrazovací hmotnostní spektrometrii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů