Advances in high-resolution cytometry of FISH dots in interphase cell nuclei
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F00%3A00005457" target="_blank" >RIV/00216224:14330/00:00005457 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advances in high-resolution cytometry of FISH dots in interphase cell nuclei
Popis výsledku v původním jazyce
Recently, we have described a high-resolution cytometry (HRCM) technique (Cytometry 36:279-293) as a reasonable compromise between flow cytometry (FCM) and laser scanning cytometry (LSCM) on one hand and confocal laser scanning microscopy (CLSM) on the other hand. Whereas FCM/LSCM and CLSM enable measuring of either large number of cells with low resolution or small number of cells with high resolution, respectively, HRCM can analyze quantities comparable to FCM/LSCM measurements (using overnight acquisition) with an accuracy comparable to CLSM. Very recently we have built a second HRCM instrument (see picture at http://www.fi.muni.cz/lom) which enables switching between conventional and confocal modes. The confocal mode is realized using a 5% Nipkow disk optimized for fluorescence imaging. It offers a better resolution but at a lower speed. The user can choose which fluorochromes are imaged in confocal mode. Thus, the system can be configured for a variety of imaging modes ranging fro
Název v anglickém jazyce
Advances in high-resolution cytometry of FISH dots in interphase cell nuclei
Popis výsledku anglicky
Recently, we have described a high-resolution cytometry (HRCM) technique (Cytometry 36:279-293) as a reasonable compromise between flow cytometry (FCM) and laser scanning cytometry (LSCM) on one hand and confocal laser scanning microscopy (CLSM) on the other hand. Whereas FCM/LSCM and CLSM enable measuring of either large number of cells with low resolution or small number of cells with high resolution, respectively, HRCM can analyze quantities comparable to FCM/LSCM measurements (using overnight acquisition) with an accuracy comparable to CLSM. Very recently we have built a second HRCM instrument (see picture at http://www.fi.muni.cz/lom) which enables switching between conventional and confocal modes. The confocal mode is realized using a 5% Nipkow disk optimized for fluorescence imaging. It offers a better resolution but at a lower speed. The user can choose which fluorochromes are imaged in confocal mode. Thus, the system can be configured for a variety of imaging modes ranging fro
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Medica
ISSN
1211-4286
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
1
Strana od-do
165
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—