Improving measurement precision using automated micro-axial tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F03%3A00009008" target="_blank" >RIV/00216224:14330/03:00009008 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14330/03:00008573
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improving measurement precision using automated micro-axial tomography
Popis výsledku v původním jazyce
Distance measurement between small targets plays an important role in human genome research. The precision of such measurements depends on the quality of images, the localisation precision of the targets and the orientation of the line connecting the targets. In micro-axial tomography, the observed objects (cells) are fixed to a glass fibre, which can be rotated. By rotating the fibre the orientation of the measured targets can be changed. The relationship between the localisation precision and the orientation of the targets has been studied in simple simulations. In micro-axial tomography, two main approaches to measurement exist. Either one high-resolution image is reconstructed from the acquired tilted images and the measurements are performed on the single image or the images in the series are measured separately and the results are combined. Both approaches are compared and discussed here.
Název v anglickém jazyce
Improving measurement precision using automated micro-axial tomography
Popis výsledku anglicky
Distance measurement between small targets plays an important role in human genome research. The precision of such measurements depends on the quality of images, the localisation precision of the targets and the orientation of the line connecting the targets. In micro-axial tomography, the observed objects (cells) are fixed to a glass fibre, which can be rotated. By rotating the fibre the orientation of the measured targets can be changed. The relationship between the localisation precision and the orientation of the targets has been studied in simple simulations. In micro-axial tomography, two main approaches to measurement exist. Either one high-resolution image is reconstructed from the acquired tilted images and the measurements are performed on the single image or the images in the series are measured separately and the results are combined. Both approaches are compared and discussed here.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IBS5004010" target="_blank" >IBS5004010: Vývoj nových diagnostických technik pro onkologii</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Biophysics of the Genome
ISBN
80-210-3226-X
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
51-53
Název nakladatele
Masaryk University
Místo vydání
Brno
Místo konání akce
Hlohovec, Czech Republic
Datum konání akce
1. 1. 2003
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—