Performance and Sensitivity Evaluation of 3-D Spot Detection Methods in Confocal Microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F15%3A00080577" target="_blank" >RIV/00216224:14330/15:00080577 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/cyto.a.22692" target="_blank" >http://dx.doi.org/10.1002/cyto.a.22692</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/cyto.a.22692" target="_blank" >10.1002/cyto.a.22692</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performance and Sensitivity Evaluation of 3-D Spot Detection Methods in Confocal Microscopy
Popis výsledku v původním jazyce
Reliable 3D detection of diffraction-limited spots in fluorescence microscopy images is an important task in subcellular observation. Generally, fluorescence microscopy images are heavily degraded by noise and non-specifically stained background, makingreliable detection a challenging task. In this work, we have studied the performance and parameter sensitivity of eight recent methods for 3D spot detection. The study is based on both 3D synthetic image data and 3D real confocal microscopy images. The synthetic images were generated using a simulator modeling the complete imaging setup, including the optical path as well as the image acquisition process. We studied the detection performance and parameter sensitivity under different noise levels and under the influence of uneven background signal. To evaluate the parameter sensitivity, we propose a novel measure based on the gradient magnitude of the F1 score.
Název v anglickém jazyce
Performance and Sensitivity Evaluation of 3-D Spot Detection Methods in Confocal Microscopy
Popis výsledku anglicky
Reliable 3D detection of diffraction-limited spots in fluorescence microscopy images is an important task in subcellular observation. Generally, fluorescence microscopy images are heavily degraded by noise and non-specifically stained background, makingreliable detection a challenging task. In this work, we have studied the performance and parameter sensitivity of eight recent methods for 3D spot detection. The study is based on both 3D synthetic image data and 3D real confocal microscopy images. The synthetic images were generated using a simulator modeling the complete imaging setup, including the optical path as well as the image acquisition process. We studied the detection performance and parameter sensitivity under different noise levels and under the influence of uneven background signal. To evaluate the parameter sensitivity, we propose a novel measure based on the gradient magnitude of the F1 score.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP302%2F12%2FG157" target="_blank" >GBP302/12/G157: Dynamika a organizace chromosomů během buněčného cyklu a při diferenciaci v normě a patologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cytometry Part A
ISSN
1552-4922
e-ISSN
—
Svazek periodika
87A
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
759-772
Kód UT WoS článku
000358643200011
EID výsledku v databázi Scopus
—