Diode laser thermal vaporization inductively coupled plasma mass spectrometry for determination of trace elements in microsamples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00057898" target="_blank" >RIV/00216224:14740/12:00057898 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diode laser thermal vaporization inductively coupled plasma mass spectrometry for determination of trace elements in microsamples
Popis výsledku v původním jazyce
A new method for determination of trace elements in submicroliter sample volumes using diode laser thermal vaporization inductively coupled mass spectrometry (DLTV ICP MS) is presented.(1) Common laser-based sample introduction methods use an expensive high-energy pulse laser, whereas DLTV employs a low-cost near infrared continuous-wave diode laser. The diode laser energy is sufficient to induce pyrolysis of the preprinted paper with depositing micro-volume samples and the generated aerosol is carriedout into the ICP MS and tested. The limits of detection of Co, Ni, Zn, Mo, Cd, Sn and Pb deposited on the preprinted paper were found to be in the range of 4 ? 300 pg. The technique was applied to determination of lead in whole blood and tin in canned food without any sample treatment. Selection of optimal conditions, experimental arrangement, raster, scan speed etc. will be discussed.
Název v anglickém jazyce
Diode laser thermal vaporization inductively coupled plasma mass spectrometry for determination of trace elements in microsamples
Popis výsledku anglicky
A new method for determination of trace elements in submicroliter sample volumes using diode laser thermal vaporization inductively coupled mass spectrometry (DLTV ICP MS) is presented.(1) Common laser-based sample introduction methods use an expensive high-energy pulse laser, whereas DLTV employs a low-cost near infrared continuous-wave diode laser. The diode laser energy is sufficient to induce pyrolysis of the preprinted paper with depositing micro-volume samples and the generated aerosol is carriedout into the ICP MS and tested. The limits of detection of Co, Ni, Zn, Mo, Cd, Sn and Pb deposited on the preprinted paper were found to be in the range of 4 ? 300 pg. The technique was applied to determination of lead in whole blood and tin in canned food without any sample treatment. Selection of optimal conditions, experimental arrangement, raster, scan speed etc. will be discussed.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů