Sensitivity of PPI analysis to differences in noise reduction strategies
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F15%3A00080949" target="_blank" >RIV/00216224:14740/15:00080949 - isvavai.cz</a>
Výsledek na webu
<a href="http://ac.els-cdn.com/S0165027015002459/1-s2.0-S0165027015002459-main.pdf?_tid=2b313bc2-4259-11e5-bb7c-00000aab0f26&acdnat=1439538824_bbe2dc8b96cdc663b6ffb54057334360" target="_blank" >http://ac.els-cdn.com/S0165027015002459/1-s2.0-S0165027015002459-main.pdf?_tid=2b313bc2-4259-11e5-bb7c-00000aab0f26&acdnat=1439538824_bbe2dc8b96cdc663b6ffb54057334360</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jneumeth.2015.06.021" target="_blank" >10.1016/j.jneumeth.2015.06.021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitivity of PPI analysis to differences in noise reduction strategies
Popis výsledku v původním jazyce
Background In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. Methods Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI ?seed? signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis.
Název v anglickém jazyce
Sensitivity of PPI analysis to differences in noise reduction strategies
Popis výsledku anglicky
Background In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. Methods Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI ?seed? signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Neuroscience Methods
ISSN
0165-0270
e-ISSN
—
Svazek periodika
253
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
15
Strana od-do
218-232
Kód UT WoS článku
000360867400022
EID výsledku v databázi Scopus
—