Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F15%3A00081636" target="_blank" >RIV/00216224:14740/15:00081636 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/elps.201400456/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elps.201400456/abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201400456" target="_blank" >10.1002/elps.201400456</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection
Popis výsledku v původním jazyce
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with (CD)-D-4 is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-(CD)-D-4 in a 60 mM MES/L-histidine BGE with 30 mu M CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC.
Název v anglickém jazyce
Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection
Popis výsledku anglicky
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with (CD)-D-4 is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-(CD)-D-4 in a 60 mM MES/L-histidine BGE with 30 mu M CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
526-533
Kód UT WoS článku
000349969700006
EID výsledku v databázi Scopus
—