CAPILLARY ELECTROPHORETIC ANALYSIS OF EXHALED BREATH CONDENSATE IN THE DIAGNOSIS OF GASTROESOPHAGEAL REFLUX DISEASE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F18%3A00106949" target="_blank" >RIV/00216224:14740/18:00106949 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/65269705:_____/18:00069837
Výsledek na webu
<a href="http://dx.doi.org/10.1515/hjic-2018-0006" target="_blank" >http://dx.doi.org/10.1515/hjic-2018-0006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/hjic-2018-0006" target="_blank" >10.1515/hjic-2018-0006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CAPILLARY ELECTROPHORETIC ANALYSIS OF EXHALED BREATH CONDENSATE IN THE DIAGNOSIS OF GASTROESOPHAGEAL REFLUX DISEASE
Popis výsledku v původním jazyce
In this work, capillary electrophoresis with contactless conductometric detection (CCD) was used for the analysis of the ionic content of exhaled breath condensate (EBC) to differentiate between healthy individuals and patients with gastroesophageal reflux disease (GERD). The exhaled breath condensate was collected using a miniature sample collection device and the content analyzed using a separation electrolyte composed of 20 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM L-histidine, 2 mM 18-Crown-6 and 30 mu M cetyltrimethylammonium bromide. The separation of anions took less than 2.5 minutes, while the cations were separated in less than 1.5 minutes. The most significantly elevated ions in the group of patients suffering from gastroesophageal reflux disease were chloride, nitrate, propionate and butyrate. Although the number of subjects was too small to draw definite conclusions with regard to the discriminatory power of these ions, the pilot data are promising for EBC as a useful non-invasive alternative for other methods used in the diagnosis of gastroesophageal reflux disease.
Název v anglickém jazyce
CAPILLARY ELECTROPHORETIC ANALYSIS OF EXHALED BREATH CONDENSATE IN THE DIAGNOSIS OF GASTROESOPHAGEAL REFLUX DISEASE
Popis výsledku anglicky
In this work, capillary electrophoresis with contactless conductometric detection (CCD) was used for the analysis of the ionic content of exhaled breath condensate (EBC) to differentiate between healthy individuals and patients with gastroesophageal reflux disease (GERD). The exhaled breath condensate was collected using a miniature sample collection device and the content analyzed using a separation electrolyte composed of 20 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM L-histidine, 2 mM 18-Crown-6 and 30 mu M cetyltrimethylammonium bromide. The separation of anions took less than 2.5 minutes, while the cations were separated in less than 1.5 minutes. The most significantly elevated ions in the group of patients suffering from gastroesophageal reflux disease were chloride, nitrate, propionate and butyrate. Although the number of subjects was too small to draw definite conclusions with regard to the discriminatory power of these ions, the pilot data are promising for EBC as a useful non-invasive alternative for other methods used in the diagnosis of gastroesophageal reflux disease.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-31945A" target="_blank" >NV17-31945A: Vývoj neinvazivní diagnostiky extraezofageálních projevů refluxní choroby jícnu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
HUNGARIAN JOURNAL OF INDUSTRY AND CHEMISTRY
ISSN
0133-0276
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
5
Strana od-do
23-27
Kód UT WoS článku
000440079700006
EID výsledku v databázi Scopus
—