Nanostructured gold electrodes for determination of glucose in blood
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F15%3A00083973" target="_blank" >RIV/00216224:14740/15:00083973 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/15:00450523
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanostructured gold electrodes for determination of glucose in blood
Popis výsledku v původním jazyce
Fast and sensitive devices for monitoring of glucose are crucial in today?s medicine. Most of the commercial glucometers are currently based on enzymatic catalysis which provides reasonable sensitivity but has a drawback in limited enzyme stability. Withthe development of novel surfaces, new generation of non-enzymatic sensors characterized by high sensitivity and stability is emerging. In this work, gelatin-templated nanostructured gold electrodes were developed and applied for non-enzymatic glucose determination. The analysis was done by direct electrochemical oxidation during cyclic voltammetry and amperometry with the limit of detection at 1.3 ?M. The ability to detect physiological levels glucose in presence of interferents was demonstrated on deproteinized human blood serum.
Název v anglickém jazyce
Nanostructured gold electrodes for determination of glucose in blood
Popis výsledku anglicky
Fast and sensitive devices for monitoring of glucose are crucial in today?s medicine. Most of the commercial glucometers are currently based on enzymatic catalysis which provides reasonable sensitivity but has a drawback in limited enzyme stability. Withthe development of novel surfaces, new generation of non-enzymatic sensors characterized by high sensitivity and stability is emerging. In this work, gelatin-templated nanostructured gold electrodes were developed and applied for non-enzymatic glucose determination. The analysis was done by direct electrochemical oxidation during cyclic voltammetry and amperometry with the limit of detection at 1.3 ?M. The ability to detect physiological levels glucose in presence of interferents was demonstrated on deproteinized human blood serum.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2015
ISBN
9788090495937
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
54-57
Název nakladatele
Institute of Analytical Chemistry of the CAS, v. v. i.
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
21. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—