Feasibility of iodine determination in pellets with Laser-Induced Breakdown Spectroscopy
Popis výsledku v původním jazyce
The work is based on iodine detection in pressed pellets using LIBS. Generally, detection of halogens using such method has been regarded challenging1. For this study a double pulse (DP)-LIBS system was employed. It consists of a Nd: YAG 266 nm ablationlaser and a Nd: YAG 1064 nm re-excitation laser, both arranged in orthogonal configuration. The mail goal was to compare different types of binders, non-conductive and conductive ones. From the first category, frequently used microcellulose and from thesecond one silver powder was used. We focused on the influence of the binder on sensitivity and changes in set of accessible lines of iodine. The observed iodine atomic and ionic lines fall to interval of 500-600 nm. Iodine emission was measured at LIBSof potassium iodide and potassium iodite salts mixed and pressed with a binder. The iodine content was in the range of several percents. Secondly we studied effect of nanoparticles on emission intensity enhancement.
Název v anglickém jazyce
Feasibility of iodine determination in pellets with Laser-Induced Breakdown Spectroscopy
Popis výsledku anglicky
The work is based on iodine detection in pressed pellets using LIBS. Generally, detection of halogens using such method has been regarded challenging1. For this study a double pulse (DP)-LIBS system was employed. It consists of a Nd: YAG 266 nm ablationlaser and a Nd: YAG 1064 nm re-excitation laser, both arranged in orthogonal configuration. The mail goal was to compare different types of binders, non-conductive and conductive ones. From the first category, frequently used microcellulose and from thesecond one silver powder was used. We focused on the influence of the binder on sensitivity and changes in set of accessible lines of iodine. The observed iodine atomic and ionic lines fall to interval of 500-600 nm. Iodine emission was measured at LIBSof potassium iodide and potassium iodite salts mixed and pressed with a binder. The iodine content was in the range of several percents. Secondly we studied effect of nanoparticles on emission intensity enhancement.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CA - Anorganická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů