Capabilities of Orthogonal Double-Pulse Laser Induced Breakdown Spectroscopy (DP LIBS) for Determination of Halogens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F13%3A00070558" target="_blank" >RIV/00216224:14740/13:00070558 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capabilities of Orthogonal Double-Pulse Laser Induced Breakdown Spectroscopy (DP LIBS) for Determination of Halogens
Popis výsledku v původním jazyce
In our work we focused on a set of affordable halogens: F, Cl, Br and I. DP-LIBS analysis of model samples containing these elements was done. Two orthogonal DP-LIBS configurations were used and the systems were compared. One system consists of two Nd: YAG lasers emitting the primary beam at 532 nm and the secondary beam at 1064 (or 532) nm. The ablation is performed in an enclosed chamber which can be also pumped and operated at a low pressure. The other system employs two Nd: YAG lasers too. The firstone is operated at 266 nm and the second one at 1064 nm. The first system uses comparable laser energies in the order of several tens of mJ. In contrast to the first system the energy difference between the lasers of the second system is nearly one order of magnitude (10 ? 20 mJ first and over 100 mJ second one). Also detection systems are substantially different. The first system uses an echelle and the second one uses a Czerny-Turner spectrograph. The both systems have ICCD detectors.
Název v anglickém jazyce
Capabilities of Orthogonal Double-Pulse Laser Induced Breakdown Spectroscopy (DP LIBS) for Determination of Halogens
Popis výsledku anglicky
In our work we focused on a set of affordable halogens: F, Cl, Br and I. DP-LIBS analysis of model samples containing these elements was done. Two orthogonal DP-LIBS configurations were used and the systems were compared. One system consists of two Nd: YAG lasers emitting the primary beam at 532 nm and the secondary beam at 1064 (or 532) nm. The ablation is performed in an enclosed chamber which can be also pumped and operated at a low pressure. The other system employs two Nd: YAG lasers too. The firstone is operated at 266 nm and the second one at 1064 nm. The first system uses comparable laser energies in the order of several tens of mJ. In contrast to the first system the energy difference between the lasers of the second system is nearly one order of magnitude (10 ? 20 mJ first and over 100 mJ second one). Also detection systems are substantially different. The first system uses an echelle and the second one uses a Czerny-Turner spectrograph. The both systems have ICCD detectors.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů