Detection of p53 Gene by Using Genomagnetic Assay Combined with Carbon Nanotube Modified Disposable Sensor Technology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F15%3A00085531" target="_blank" >RIV/00216224:14740/15:00085531 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081707:_____/15:00456710
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/elan.201400731/epdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elan.201400731/epdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400731" target="_blank" >10.1002/elan.201400731</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of p53 Gene by Using Genomagnetic Assay Combined with Carbon Nanotube Modified Disposable Sensor Technology
Popis výsledku v původním jazyce
Electrochemical monitoring of DNA hybridization related to p53 gene sequence was investigated using genomagnetic assay combined with single walled carbon nanotube (SWCNT) modified pencil graphite electrodes (PGEs). The hybridization was performed eitherat magnetic beads (MB) surface or in solution. The enhanced guanine signal was obtained using SWCNT-PGEs compared to one obtained by unmodified PGEs. The selectivity of genomagnetic assay was tested under optimum conditions. The DLs were calculated as 0.88 mu M and 0.11 mu M for hybridization performed at MB surface and solution, respectively. This selective, practical and cost effective genomagnetic assay combined with SWCNT-PGEs is reported herein for the first time.
Název v anglickém jazyce
Detection of p53 Gene by Using Genomagnetic Assay Combined with Carbon Nanotube Modified Disposable Sensor Technology
Popis výsledku anglicky
Electrochemical monitoring of DNA hybridization related to p53 gene sequence was investigated using genomagnetic assay combined with single walled carbon nanotube (SWCNT) modified pencil graphite electrodes (PGEs). The hybridization was performed eitherat magnetic beads (MB) surface or in solution. The enhanced guanine signal was obtained using SWCNT-PGEs compared to one obtained by unmodified PGEs. The selectivity of genomagnetic assay was tested under optimum conditions. The DLs were calculated as 0.88 mu M and 0.11 mu M for hybridization performed at MB surface and solution, respectively. This selective, practical and cost effective genomagnetic assay combined with SWCNT-PGEs is reported herein for the first time.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F11%2F1638" target="_blank" >GAP206/11/1638: Nové elektrochemické senzory a detekční techniky pro analýzu struktury a interakcí nukleových kyselin</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1579-1586
Kód UT WoS článku
000357408900006