Deveopment of a microfluidic specimenpreparation device for time-resolved cryo-electron microscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F16%3A00094149" target="_blank" >RIV/00216224:14740/16:00094149 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Deveopment of a microfluidic specimenpreparation device for time-resolved cryo-electron microscopy
Popis výsledku v původním jazyce
The goal of structural biology is to be able to understand how macromolecular complex functions. In traditional, non-time-resolved cryoelectron microscopy (cryo-EM), this is accomplished by determination of static structures. Existing time-resolved techniques are difficult or inefficient, and thus have been rarely used. The goal of this proposal is to construct a customized cryo-preparation device specifically for the microfluidics-based time-resolved method that I previously helped develop. The steps required for time-resolved cryo-EM are, as quickly as possible: 1) to initiate a chemical reaction, 2) to form an aqueous layer thin enough to transmit the electron beam, and 3) to arrest the chemical reaction in cryogen. The microfluidics-based method makes use of a device which mixes two components, sprays the mixture onto an EM grid, and then plunges the grid into cryogen.
Název v anglickém jazyce
Deveopment of a microfluidic specimenpreparation device for time-resolved cryo-electron microscopy
Popis výsledku anglicky
The goal of structural biology is to be able to understand how macromolecular complex functions. In traditional, non-time-resolved cryoelectron microscopy (cryo-EM), this is accomplished by determination of static structures. Existing time-resolved techniques are difficult or inefficient, and thus have been rarely used. The goal of this proposal is to construct a customized cryo-preparation device specifically for the microfluidics-based time-resolved method that I previously helped develop. The steps required for time-resolved cryo-EM are, as quickly as possible: 1) to initiate a chemical reaction, 2) to form an aqueous layer thin enough to transmit the electron beam, and 3) to arrest the chemical reaction in cryogen. The microfluidics-based method makes use of a device which mixes two components, sprays the mixture onto an EM grid, and then plunges the grid into cryogen.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Počet stran výsledku
3
Místo vydání
Brno
Název nakladatele resp. objednatele
Instruct Academic Services Ltd.
Verze
—