Oxygen-Rich Plasma-Polymerized Coatings for QCM Biosensing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F20%3A00117501" target="_blank" >RIV/00216224:14740/20:00117501 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/abstract/document/9242164" target="_blank" >https://ieeexplore.ieee.org/abstract/document/9242164</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EFRE47760.2020.9242164" target="_blank" >10.1109/EFRE47760.2020.9242164</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Oxygen-Rich Plasma-Polymerized Coatings for QCM Biosensing
Popis výsledku v původním jazyce
Thin reactive polymer surfaces are attractive in the field of bio applications, in particular, when they have the ability to bind biomolecules while providing a great level of stability in aqueous environment. Plasma polymerization techniques enable a fast and eco-friendly procedure for the preparation of thin functional polymer films. In this paper we report on the generation of highly functional oxygen-rich plasma-polymerized (pp) coatings with great level of stability in water. A quartz crystal microbalance (QCM) biosensor was successfully developed by using a plasma polymer film as a matrix layer for antibody immobilization. The developed QCM biosensor presented a stable baseline during the measurements and exhibited selective and high response to the analyte.
Název v anglickém jazyce
Oxygen-Rich Plasma-Polymerized Coatings for QCM Biosensing
Popis výsledku anglicky
Thin reactive polymer surfaces are attractive in the field of bio applications, in particular, when they have the ability to bind biomolecules while providing a great level of stability in aqueous environment. Plasma polymerization techniques enable a fast and eco-friendly procedure for the preparation of thin functional polymer films. In this paper we report on the generation of highly functional oxygen-rich plasma-polymerized (pp) coatings with great level of stability in water. A quartz crystal microbalance (QCM) biosensor was successfully developed by using a plasma polymer film as a matrix layer for antibody immobilization. The developed QCM biosensor presented a stable baseline during the measurements and exhibited selective and high response to the analyte.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
7th International Congress on Energy Fluxes and Radiation Effects (EFRE) 2020
ISBN
9781728126852
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1087-1091
Název nakladatele
IEEE
Místo vydání
Tomsk
Místo konání akce
Tomsk
Datum konání akce
1. 1. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—