The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the Sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in mug) for maximum volume (500 mL) of the preconcentrated sample were as follows: DLZn = 1.049, DLNi = 0.867, DLCr 0.281, DLFe = 0.512, DLV = 0.549, DLPb = 0.619, DLCo = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis.
Název v anglickém jazyce
Determination of Metals in Drinking, Surface and Waste Water by XRF Spectrometry after Preconcentration of Sample on Ion - exchange Filter
Popis výsledku anglicky
The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the Sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in mug) for maximum volume (500 mL) of the preconcentrated sample were as follows: DLZn = 1.049, DLNi = 0.867, DLCr 0.281, DLFe = 0.512, DLV = 0.549, DLPb = 0.619, DLCo = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chem. Anal.
ISSN
0009-2223
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
10
Strana od-do
55-64