Stříbrná kompozitní elektroda pro voltametrické stanovení halogenidů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F04%3A00001586" target="_blank" >RIV/00216275:25310/04:00001586 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/04:00101056 RIV/00216208:11110/04:00007957
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Silver Composite Electrode for Voltammetric Determination of Halogenides
Popis výsledku v původním jazyce
The application of the silver composite electrode prepared from silver, graphite powder and methacrylate resin for the voltammetric determination of halogenide ions was studied. Cathodic direct current (DC) as well as differential pulse (DP) stripping voltammetry (DPV) enable direct determination of chloride, bromide, as well as iodide ions. The achieved limits of detection for all determined ions are sufficient for practical analytical purposes (tap water, natural water, etc.) and results reported in this paper are fully comparable with results achieved using other electrodes. The possibilities of sample analysis without elimination of the presence of surface-active substances or of dissolved oxygen were studied. The silver composite electrode represents a suitable sensor for analytical purposes and seems to be promising for replacement of electrodes in many cases.
Název v anglickém jazyce
Silver Composite Electrode for Voltammetric Determination of Halogenides
Popis výsledku anglicky
The application of the silver composite electrode prepared from silver, graphite powder and methacrylate resin for the voltammetric determination of halogenide ions was studied. Cathodic direct current (DC) as well as differential pulse (DP) stripping voltammetry (DPV) enable direct determination of chloride, bromide, as well as iodide ions. The achieved limits of detection for all determined ions are sufficient for practical analytical purposes (tap water, natural water, etc.) and results reported in this paper are fully comparable with results achieved using other electrodes. The possibilities of sample analysis without elimination of the presence of surface-active substances or of dissolved oxygen were studied. The silver composite electrode represents a suitable sensor for analytical purposes and seems to be promising for replacement of electrodes in many cases.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F02%2F0011" target="_blank" >GA101/02/0011: Nový přístup k analýze dynamických vlastností nelineárních vazebných elementů používaných v dynamice rotorových soustav</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
ISSN 0003-271
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
26
Strana od-do
603-628
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—