Bioafinitní technika pro kvalitativní analýzu potravních alergenů založená na magnetickém mikročipu.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F07%3A00005754" target="_blank" >RIV/00216275:25310/07:00005754 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chip-based Magnetic Bioaffinity Technique Adapted for Qualitative Analysis of Food Allergens
Popis výsledku v původním jazyce
There is a continuous push to miniaturize and integrate as many laboratory instrumentation pieces as possible in the quest for a ?lab-on-chip?. Parallel to the boom of microfluidic systems, nanomaterials with paramagnetic properties have become a hot topic in recent research. Using carriers with magnetic property overcomes many of the problems associated with the use of liquid gel slurries. Magnetic particles provide universal system with additional convenience, consistency, stability, ease of handlingand exceptional flexibility compared to standard chromatography resins. We present examples of bioanalysis based on the self-organization of superparamagnetic beads under a magnetic field in a simple well-established microfluidic device fabricated in polydimethylsiloxane (PDMS) by soft lithography and rapid prototyping. As previously published by our research group, the microanalytical system with plug of bio-active beads profits from a large surface-to-volume ratio and minimal diffusion
Název v anglickém jazyce
Chip-based Magnetic Bioaffinity Technique Adapted for Qualitative Analysis of Food Allergens
Popis výsledku anglicky
There is a continuous push to miniaturize and integrate as many laboratory instrumentation pieces as possible in the quest for a ?lab-on-chip?. Parallel to the boom of microfluidic systems, nanomaterials with paramagnetic properties have become a hot topic in recent research. Using carriers with magnetic property overcomes many of the problems associated with the use of liquid gel slurries. Magnetic particles provide universal system with additional convenience, consistency, stability, ease of handlingand exceptional flexibility compared to standard chromatography resins. We present examples of bioanalysis based on the self-organization of superparamagnetic beads under a magnetic field in a simple well-established microfluidic device fabricated in polydimethylsiloxane (PDMS) by soft lithography and rapid prototyping. As previously published by our research group, the microanalytical system with plug of bio-active beads profits from a large surface-to-volume ratio and minimal diffusion
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The proceedings of MicroTAS 2007 Conference
ISBN
978-0-9798064-0-7
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
637-639
Název nakladatele
Chemical and Biological Microsystems Society
Místo vydání
Tokyo
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—