Stanovení beta-karotenu v lidské plazmě pomocí HPLC s UV detekcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F07%3A00006169" target="_blank" >RIV/00216275:25310/07:00006169 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of beta-carotene in human plasma by HPLC with ultraviolet detection
Popis výsledku v původním jazyce
Beta-carotene plays an important role in biological systems. It protects against the action of some reactive oxygen and nitrogen species. A method for determination of beta-carotene in human plasma has been developed and evaluated. Chromatography was accomplished using isocratic elution on LiChrocart 125-4 Purospher RP-18e, 5 um, column. The mixture of methanol and ethanol (75:25, v/v) was used as a mobile phase. As internal standard was chosen retinyl palmitate. The analytical performance of this method is satisfactory, both intra-assay and inter-assay were with coefficients of variation below 10%, recovery was between 90-110%. The calibration curve was linear in the whole range tested (0.02-2.00) umol/L. The detection limit was 0.5 pmol/20 ul inject.This assay is a suitable and reproducible HPLC method for the determination of beta-carotene in human plasma. Acknowledgments. This work was supported by grant MSM0021627502.
Název v anglickém jazyce
Determination of beta-carotene in human plasma by HPLC with ultraviolet detection
Popis výsledku anglicky
Beta-carotene plays an important role in biological systems. It protects against the action of some reactive oxygen and nitrogen species. A method for determination of beta-carotene in human plasma has been developed and evaluated. Chromatography was accomplished using isocratic elution on LiChrocart 125-4 Purospher RP-18e, 5 um, column. The mixture of methanol and ethanol (75:25, v/v) was used as a mobile phase. As internal standard was chosen retinyl palmitate. The analytical performance of this method is satisfactory, both intra-assay and inter-assay were with coefficients of variation below 10%, recovery was between 90-110%. The calibration curve was linear in the whole range tested (0.02-2.00) umol/L. The detection limit was 0.5 pmol/20 ul inject.This assay is a suitable and reproducible HPLC method for the determination of beta-carotene in human plasma. Acknowledgments. This work was supported by grant MSM0021627502.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Vitamins 2007 - Nutrition and Diagnostics
ISBN
978-80-7194-937-4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
216
Název nakladatele
Univerzita Pardubice
Místo vydání
Pardubice
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—