Voltametrické stanovení rtuti pomocí zlaté rotační diskové elektrody v kombinaci s metodou studených par
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F07%3A00006452" target="_blank" >RIV/00216275:25310/07:00006452 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25510/07:00005035
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Proposal of Mercury Isolation Procedure Using Cold Vapor Method in Combination with Voltammetric Determination Using Rotating Gold Electrode
Popis výsledku v původním jazyce
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation.This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26?10-10 mol L-1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23?10-11 mol L-1 (analyzing a greater sample volume the determined concentration could be lower).
Název v anglickém jazyce
Proposal of Mercury Isolation Procedure Using Cold Vapor Method in Combination with Voltammetric Determination Using Rotating Gold Electrode
Popis výsledku anglicky
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation.This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26?10-10 mol L-1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23?10-11 mol L-1 (analyzing a greater sample volume the determined concentration could be lower).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1895-1066
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—