Proposal of Mercury Isolation Procedure Using Cold Vapor Method in Combination with Voltammetric Determination Using Totating Gold Electrode
Popis výsledku v původním jazyce
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury was proposed. This treatment consists from polishing of the electrode surface, electrochemical cycling, and activation. The detection limit, achieved using this way prepared working electrode, amounted to 8.26*10-10 mol L-1 for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation fromcomplicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water detection limit was 6.23*10-11 mol L-1 (analyzing greater sample volume the determined concentration could be lower)
Název v anglickém jazyce
Proposal of Mercury Isolation Procedure Using Cold Vapor Method in Combination with Voltammetric Determination Using Totating Gold Electrode
Popis výsledku anglicky
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury was proposed. This treatment consists from polishing of the electrode surface, electrochemical cycling, and activation. The detection limit, achieved using this way prepared working electrode, amounted to 8.26*10-10 mol L-1 for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation fromcomplicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water detection limit was 6.23*10-11 mol L-1 (analyzing greater sample volume the determined concentration could be lower)
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1895-1066
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
7
Strana od-do
479-495
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—