Gradient HPLC: Gradient System Selection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F09%3A00008428" target="_blank" >RIV/00216275:25310/09:00008428 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Gradient HPLC: Gradient System Selection
Popis výsledku v původním jazyce
Gradient elution is widely used for the separation of complex samples in reversed-phase high-performance liquid chromatography systems and ion-exchange systems. The theory of gradient elution has now been elaborated so that it allows predicting the retention and the resolution of sample compounds in reversed-phase, ion-exchange, and normal-phase systems for almost any combination of gradient profile and relationship between the retention and mobile-phase composition. The most important sources of errorsin the prediction and optimization of gradient elution are the gradient dwell volume and the preferential adsorption of the strong solvents, especially in normal-phase (adsorption) chromatography. The gradient dwell volume effects are more important inmicro-LC techniques than in conventional LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow splitting is used, but their effects can be taken into account in predictive c
Název v anglickém jazyce
Gradient HPLC: Gradient System Selection
Popis výsledku anglicky
Gradient elution is widely used for the separation of complex samples in reversed-phase high-performance liquid chromatography systems and ion-exchange systems. The theory of gradient elution has now been elaborated so that it allows predicting the retention and the resolution of sample compounds in reversed-phase, ion-exchange, and normal-phase systems for almost any combination of gradient profile and relationship between the retention and mobile-phase composition. The most important sources of errorsin the prediction and optimization of gradient elution are the gradient dwell volume and the preferential adsorption of the strong solvents, especially in normal-phase (adsorption) chromatography. The gradient dwell volume effects are more important inmicro-LC techniques than in conventional LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow splitting is used, but their effects can be taken into account in predictive c
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Encyclopedia of Chromatography
ISBN
978-1-4200-8459-7
Počet stran výsledku
13
Strana od-do
—
Počet stran knihy
2850
Název nakladatele
CRC Press
Místo vydání
London
Kód UT WoS kapitoly
—