Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silicacatalysts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39881657" target="_blank" >RIV/00216275:25310/11:39881657 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.talanta.2010.11.047" target="_blank" >http://dx.doi.org/10.1016/j.talanta.2010.11.047</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2010.11.047" target="_blank" >10.1016/j.talanta.2010.11.047</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silicacatalysts
Popis výsledku v původním jazyce
The method for the analysis of vanadium in V-HMS catalysts using LIBS was suggested. Commercially available LIBS spectrometer was calibrated with the aid of authentic V-HMS samples previously analyzed by ICP OES. Deposition of the sample on the surface of adhesive tape was adopted as a sample preparation method. Strong matrix effect connected with the catalyst preparation technique was observed. The concentration range of V in the set of nine calibration standards was 1.3-4.5% (w/w). Comparable resultsof LIBS and ED XRF were obtained if the same set of standards was used for calibration of both methods and V was measured in the same type of real samples.
Název v anglickém jazyce
Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silicacatalysts
Popis výsledku anglicky
The method for the analysis of vanadium in V-HMS catalysts using LIBS was suggested. Commercially available LIBS spectrometer was calibrated with the aid of authentic V-HMS samples previously analyzed by ICP OES. Deposition of the sample on the surface of adhesive tape was adopted as a sample preparation method. Strong matrix effect connected with the catalyst preparation technique was observed. The concentration range of V in the set of nine calibration standards was 1.3-4.5% (w/w). Comparable resultsof LIBS and ED XRF were obtained if the same set of standards was used for calibration of both methods and V was measured in the same type of real samples.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP106%2F10%2F0196" target="_blank" >GAP106/10/0196: Pokročilé nanostrukturní katalyzátory na bázi vanadu pro oxidativně dehydrogenační reakce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1659-1664
Kód UT WoS článku
000287110100051
EID výsledku v databázi Scopus
—