Analysis of Ti in Textile Stippled by TiO2 Nanoparticle Sol Using Double-Pulse LIBS AND ED XRF Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39885421" target="_blank" >RIV/00216275:25310/11:39885421 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24410/11:#0000977
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Ti in Textile Stippled by TiO2 Nanoparticle Sol Using Double-Pulse LIBS AND ED XRF Spectrometry
Popis výsledku v původním jazyce
Double-pulse LIBS and ED XRF usabilities for quantitative analysis of Ti in samples of cotton, wool, and viscose fabrics were compared to each other. The analyzed samples were prepared by stippling a particular fabric with TiO2 nanoparticle sol (particlesize 100 nm). Both spectrometers were calibrated with the aid of the same sets of authentic fabric samples previously analyzed by ICP OES after the microwave digestion. Average values of the Ti concentration calculated from five repeated measurements ofthe same sample obtained by LIBS and ED XRF were comparable for all types of the tested materials (100?(CTi-LIBS/CTi-ED XRF)) 96- 109%), but the precision of analysis expressed as RSD (relative standard deviation) was usually better for ED XRF (RSD LIBSfrom 9 to 25%, RSD ED XRF from 3 to 17%). Poor RSD values of LIBS measurements were observed mainly in the case of samples with lower areal weights.
Název v anglickém jazyce
Analysis of Ti in Textile Stippled by TiO2 Nanoparticle Sol Using Double-Pulse LIBS AND ED XRF Spectrometry
Popis výsledku anglicky
Double-pulse LIBS and ED XRF usabilities for quantitative analysis of Ti in samples of cotton, wool, and viscose fabrics were compared to each other. The analyzed samples were prepared by stippling a particular fabric with TiO2 nanoparticle sol (particlesize 100 nm). Both spectrometers were calibrated with the aid of the same sets of authentic fabric samples previously analyzed by ICP OES after the microwave digestion. Average values of the Ti concentration calculated from five repeated measurements ofthe same sample obtained by LIBS and ED XRF were comparable for all types of the tested materials (100?(CTi-LIBS/CTi-ED XRF)) 96- 109%), but the precision of analysis expressed as RSD (relative standard deviation) was usually better for ED XRF (RSD LIBSfrom 9 to 25%, RSD ED XRF from 3 to 17%). Poor RSD values of LIBS measurements were observed mainly in the case of samples with lower areal weights.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FT-TA5%2F007" target="_blank" >FT-TA5/007: Pokročilý výzkum nanomateriálů pro textil</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Applied Spectroscopy
ISSN
0021-9037
e-ISSN
—
Svazek periodika
78
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
673-679
Kód UT WoS článku
000297619800009
EID výsledku v databázi Scopus
—