Voltammetric Determination of Folic Acid Using Liquid Mercury Free Silver Amalgam Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39892226" target="_blank" >RIV/00216275:25310/11:39892226 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Folic Acid Using Liquid Mercury Free Silver Amalgam Electrode
Popis výsledku v původním jazyce
The electrochemical behavior of folic acid (FA) on a polished silver solid amalgam electrode (p-AgSAE), as a liquid mercury free electrode, has been studied in this paper. Differential pulse voltammetry (DPV) was found as a suitable method for voltammetric determination of folic acid. A limit of detection as 5.88?10-10 M (after 60 s of accumulation) was calculated for FA determination in an acetate buffer (pH 5). P-AgSAE in connection with DPV with optimized parameters was successfully applied for the determined folic acid compound in two types of vitamin preparations and two kinds of fruit juices. It was found that p-AgSAE is an appropriate tool for voltammetric determination of this vitamin in these real samples and it can replace mercury electrodesin voltammetric analysis of folic acid.
Název v anglickém jazyce
Voltammetric Determination of Folic Acid Using Liquid Mercury Free Silver Amalgam Electrode
Popis výsledku anglicky
The electrochemical behavior of folic acid (FA) on a polished silver solid amalgam electrode (p-AgSAE), as a liquid mercury free electrode, has been studied in this paper. Differential pulse voltammetry (DPV) was found as a suitable method for voltammetric determination of folic acid. A limit of detection as 5.88?10-10 M (after 60 s of accumulation) was calculated for FA determination in an acetate buffer (pH 5). P-AgSAE in connection with DPV with optimized parameters was successfully applied for the determined folic acid compound in two types of vitamin preparations and two kinds of fruit juices. It was found that p-AgSAE is an appropriate tool for voltammetric determination of this vitamin in these real samples and it can replace mercury electrodesin voltammetric analysis of folic acid.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Chimica Slovenica
ISSN
1318-0207
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
SI - Slovinská republika
Počet stran výsledku
9
Strana od-do
776-784
Kód UT WoS článku
000298811900019
EID výsledku v databázi Scopus
—