Path to epsilon - HNIW with Reduced Sensitivity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39892492" target="_blank" >RIV/00216275:25310/11:39892492 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Path to epsilon - HNIW with Reduced Sensitivity
Popis výsledku v původním jazyce
New purifn. method was applied to obtain epsilon HNIW which has low impact sensitivity. The method is based on removing the impurities from a soln. of alpha HNIW by a chem. reaction to obtain pure epsilon form. For comparison, selected different published methods for recrystn. of HNIW to obtain the epsilon form were studied. Methods are based on solvent-antisolvent technique. The optimum parameters were applied to enhance the crystal size and shape of epsilon-HNIW The thermal stability of the prepd. samples was studied by using DTA technique (DTA). Qual. anal. of the crystal size and shape was done using scanning electron microscope (SEM) devise. Impact sensitivity was measured by falling hammer test. The impact sensitivity of HNIW decreases by obtaining small particles with regular shape. While the obtained crystals from the new method has regular smooth surface, with small particle size and its impact sensitivity is lower than RDX and HMX.
Název v anglickém jazyce
Path to epsilon - HNIW with Reduced Sensitivity
Popis výsledku anglicky
New purifn. method was applied to obtain epsilon HNIW which has low impact sensitivity. The method is based on removing the impurities from a soln. of alpha HNIW by a chem. reaction to obtain pure epsilon form. For comparison, selected different published methods for recrystn. of HNIW to obtain the epsilon form were studied. Methods are based on solvent-antisolvent technique. The optimum parameters were applied to enhance the crystal size and shape of epsilon-HNIW The thermal stability of the prepd. samples was studied by using DTA technique (DTA). Qual. anal. of the crystal size and shape was done using scanning electron microscope (SEM) devise. Impact sensitivity was measured by falling hammer test. The impact sensitivity of HNIW decreases by obtaining small particles with regular shape. While the obtained crystals from the new method has regular smooth surface, with small particle size and its impact sensitivity is lower than RDX and HMX.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Energetic Materials
ISSN
1733-7178
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
10
Strana od-do
173-182
Kód UT WoS článku
000299916900003
EID výsledku v databázi Scopus
—